{"product_id":"mc-ghao11-51309540-175-analog-output-module-honeywell","title":"MC-GHAO11 51309540-175 Analog Output Module | Honeywell","description":"\u003cp\u003eConfigured for 16-channel analog output termination and loop control within FSC distributed control platforms, the \u003cstrong\u003eHoneywell MC-GHAO11 51309540-175\u003c\/strong\u003e (\u003cstrong\u003eMC-GHAO11\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution of precision current signal transmission.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-GHAO11 (51309540-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.1 x 12 x 4.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane-supplied DC power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module (Field Termination Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0-21.1 mA adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05% current linearity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadback Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-4% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e100 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Capacity\u003c\/td\u003e\n\u003ctd\u003e24 mA absolute maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eFSC System \/ DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates robust channel-to-channel isolation networks across all 16 independent output loops to eliminate ground potential differentials and common-mode interference. Precision digital-to-analog converters condition 0-21.1 mA signals while preserving 4-20 mA HART loop protocol compatibility for bi-directional communication with intelligent field actuators. Hardware diagnostic circuits perform continuous cycle checks every minute, supporting rapid failover response times under 20 ms during fault conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What response time is maintained by the hardware failover mechanism during a fault?\u003c\/p\u003e\n\u003cp\u003eA: The module executes fault detection and switches to a safe state within a failover response time of less than 20 ms.\u003c\/p\u003e\n\u003cp\u003eQ: How many independent control loops does the module support simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: The assembly provides 16 fully isolated analog output channels for independent loop control and signal modulation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure cabinet backplane power is de-energized before mounting the module onto the designated FSC system rack chassis.\u003c\/li\u003e\n\u003cli\u003eAlign the hardware card edges with cabinet guide slots and press firmly until backplane bus connectors seat fully.\u003c\/li\u003e\n\u003cli\u003eTerminate field actuator signal wiring at the onboard screw terminal blocks, verifying correct loop polarity for each of the 16 channels.\u003c\/li\u003e\n\u003cli\u003eSecure shield drain wires to the cabinet grounding bar to maintain electromagnetic immunity against high-frequency plant noise.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67667382960437,"sku":"MC-GHAO11 51309540-175","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51309540-175_Cocoai.png?v=1791612625","url":"https:\/\/www.5gplc.com\/products\/mc-ghao11-51309540-175-analog-output-module-honeywell","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}