{"product_id":"lg1093aa04-honeywell-ultraviolet-flame-sensor","title":"LG1093AA04 | Honeywell | Ultraviolet Flame Sensor","description":"\u003cp\u003eConfigured for combustion monitoring in burner management systems, the \u003cstrong\u003eHoneywell LG1093AA04\u003c\/strong\u003e (\u003cstrong\u003eLG1093AA04\u003c\/strong\u003e Ultraviolet Flame Sensor) provides direct physical execution of flame detection via UV spectroscopy. The sensor serves as the primary detection element utilized to execute rapid flame monitoring across industrial furnace and boiler platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLG1093AA04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0 to 762 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTSI Mechanical Monitoring and Signal Validation\u003c\/h3\u003e\n\u003cp\u003eThe LG1093AA04 employs UV spectroscopy to isolate the specific spectral signatures emitted during combustion, facilitating high-speed flame discrimination. By maintaining a high sensitivity of 0.5 uA\/mW, the sensor effectively filters out ambient light interference to ensure distinct flame state reporting. The internal circuitry utilizes cross-talk suppression to maintain signal integrity when multiple sensors are mounted in close proximity within a multi-burner array. The output stage provides a binary open\/grounded signal, which must be validated against the controller's logic thresholds to confirm valid flame presence within the combustion chamber.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the LG1093AA04 be used in high-vibration environments?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the sensor is constructed for industrial service. However, ensure that the M12 connector is properly secured and that shielded cabling is used to prevent induced noise in the signal line, which could be misinterpreted as flame flicker or loss.\u003c\/p\u003e\n\u003cp\u003eQ: Is the sensor output signal compatible with standard PLC digital input cards?\u003c\/p\u003e\n\u003cp\u003eA: The sensor provides an open\/grounded output. Verify that the input module is configured to match the voltage level and logic state (sink\/source) of the sensor output to ensure correct detection of the flame\/no-flame status.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the mounting position provides a direct line-of-sight to the flame root, within the 762 mm maximum detection range.\u003c\/li\u003e\n\u003cli\u003eInstall the sensor using the provided M12 connector, ensuring the cable is routed away from high-voltage ignition sources to avoid EMI interference.\u003c\/li\u003e\n\u003cli\u003eVerify the IP65 seal by tightening the connector and inspecting the enclosure for debris or damage that could compromise environmental protection.\u003c\/li\u003e\n\u003cli\u003ePerform an initial flame-on\/flame-off test to verify that the controller correctly maps the sensor's open\/grounded signal transitions to the burner management logic.\u003c\/li\u003e\n\u003cli\u003ePeriodically inspect the optical lens for soot accumulation, as surface fouling will reduce spectral sensitivity and may lead to false-negative flame loss indications.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52976031400245,"sku":"LG1093AA04","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/LG1093AA04.png?v=1780991408","url":"https:\/\/www.5gplc.com\/products\/lg1093aa04-honeywell-ultraviolet-flame-sensor","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}