{"product_id":"kl2001x1-bd1-deltav-ethernet-i-o-card-emerson","title":"KL2001X1-BD1 DeltaV Ethernet I\/O Card | Emerson","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson KL2001X1-BD1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKL2001X1-BD1\u003c\/strong\u003e Ethernet I\/O Card, operates as a dedicated hardware component for high-speed Ethernet communication and I\/O bus interface processing within DeltaV control system architectures. The module establishes direct network telemetry and physical layer interface control, powered by an internal 24 VDC bus draw at 325 mA under ISA-S71.04-1985 Class G3 environmental rating standards.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKL2001X1-BD1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 325 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock\u003c\/td\u003e\n\u003ctd\u003e10 g half-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Vibration\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak from 2 to 13.2 Hz, 0.7 g from 13.2 to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3 harsh environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eDeltaV DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet I\/O Cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Ethernet I\/O module integrates channel-to-channel isolation architecture across the field interface side to shield host network processors from field-induced surge voltages and ground loops. Designed for seamless integration into 4-20 mA HART loop protocol networks and FOUNDATION Fieldbus segments, the module maintains signal pass-through fidelity without introducing frame conversion latency. Onboard hardware design accounts for cold junction compensation thermal references, guaranteeing precise signal evaluation and timing synchronization during ambient panel temperature transitions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the KL2001X1-BD1 Ethernet I\/O Card support online insertion and removal (hot-swapping)?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is designed for hot-swapping on an active DeltaV I\/O carrier, provided host system redundancy rules are observed to prevent active network dropping.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary power supply requirement for operating the KL2001X1-BD1?\u003c\/p\u003e\n\u003cp\u003eA: The card requires a continuous 24 VDC supply voltage draw of 325 mA sourced directly through the carrier backplane interface.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental protection rating does the card circuitry feature for corrosive atmospheres?\u003c\/p\u003e\n\u003cp\u003eA: The assembly is rated to ISA-S71.04-1985 Class G3 for airborne contaminants, allowing deployment in harsh chemical environments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm carrier slot assignment within the DeltaV node before inserting the card module.\u003c\/li\u003e\n\u003cli\u003eAlign the module card edges with the carrier guide rails and push firmly until top and bottom retention latches snap securely into place.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC power supply to the carrier bus is within specified operating limits prior to system commissioning.\u003c\/li\u003e\n\u003cli\u003eRoute industrial Ethernet cables through designated cable management channels, maintaining separation from high-voltage power wiring.\u003c\/li\u003e\n\u003cli\u003eConnect network cables to the RJ-45 interface ports until retaining clips lock in position.\u003c\/li\u003e\n\u003cli\u003eEnsure the enclosure cabinet frame ground is bonded to the main station earth ground grid to preserve G3 compliance and surge isolation circuits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53445568889141,"sku":"KL2001X1-BD1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KL2101X1-BA1_6b8db36d-a018-46f0-87c9-e00d3691fe4f.png?v=1788338636","url":"https:\/\/www.5gplc.com\/products\/kl2001x1-bd1-deltav-ethernet-i-o-card-emerson","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}