{"product_id":"kj1501x1-pw1-dc-power-supply-module-emerson","title":"KJ1501X1-PW1 DC Power Supply Module | Emerson","description":"\u003cp\u003eConfigured for stable voltage distribution in DeltaV distributed control system topologies, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KJ1501X1-PW1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eKJ1501X1-PW1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDC Power Supply Module) provides direct physical\/electrical execution. This module converts raw DC input potentials into regulated multi-rail outputs required to maintain active controller logic and backplane communication circuitry across the system architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKJ1501X1-PW1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DeltaV power supply chassis footprint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.2 W total power dissipation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC or 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC, 5.1 VDC, 3.4 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 13 A (at 12 VDC input); 8 A (at 24 VDC input)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShock Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7g (13.2-150 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Matrix\u003c\/h3\u003e\n\u003cp\u003eThe power supply architecture utilizes high-frequency switching regulation to maintain output stability under varying load conditions. Integrated design parameters ensure comprehensive channel-to-channel isolation between the raw DC input and the regulated output voltage rails. This structural segregation prevents common-mode noise, switching transients, and input side voltage fluctuations from coupling into sensitive 4-20 mA HART loop protocol lines or controller logic registers, preserving integrity across the backplane communication bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this power supply module support parallel load sharing when configured with redundant power units?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is engineered for parallel load-sharing applications. When installed in a redundant chassis configuration, the units distribute the total current demand, preventing individual module thermal overload while ensuring seamless output if a single unit fails.\u003c\/p\u003e\n\u003cp\u003eQ: Is this power supply capable of hot-swap maintenance during system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports live hot-swap replacement on an energized DeltaV carrier base. The internal power-up sequencing logic prevents output voltage spikes or backplane reset events during insertion.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Secure the module housing onto a standard 35 mm DIN rail. Ensure the mechanical grounding tab snaps firmly into the rail to establish a low-impedance path for chassis-level electromagnetic interference suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Selection\u003c\/strong\u003e: Verify the DC source matches the module input range (12 VDC or 24 VDC) prior to landing field wires. Incorrect input potential selection will trigger internal protection circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Route all input and output power leads in separate conduits away from sensitive low-voltage instrumentation cabling to prevent inductive coupling of switching noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Maintain the specified minimum air clearance above and below the module housing to allow for natural convection. Operating in an environment at the upper limit of +70 deg C requires active cabinet ventilation to prevent derating of the output current capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52922277495093,"sku":"KJ1501X1-PW1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KJ1501X1-BC1_962070b2-2b76-4d65-aacf-689b4c1d2d6f.png?v=1779703485","url":"https:\/\/www.5gplc.com\/products\/kj1501x1-pw1-dc-power-supply-module-emerson","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}