{"product_id":"is200vaich1cbr-ge-mark-vi-analog-input-vme-module","title":"IS200VAICH1CBR GE Mark VI Analog Input VME Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200VAICH1CBR\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200VAICH1\u003c\/strong\u003e Analog Input VME Module, operates as a dedicated hardware component for analog signal acquisition and real-time data processing within Mark VI turbine control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VAICH1CBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12 cm x 15.3 cm x 6.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard VME backplane power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eVMEbus form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMark VI Speedtronic System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eAMD Ryzen Embedded V1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eUp to 8 GB DDR4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e64 GB eMMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 SIL 3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; Logic Execution\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Mark VI control rack backplane via its VMEbus architecture. High-speed backplane bus communication velocity allows rapid analog signal digitizing and processing without introducing bottleneck latencies during critical control loops.\u003c\/p\u003e\n\u003cp\u003eProcessing capabilities are backed by an AMD Ryzen Embedded V1000 processor and up to 8 GB DDR4 memory, enabling on-card real-time diagnostics and firmware execution stored in 64 GB eMMC non-volatile flash storage. The board architecture supports I\/O density scaling across system slots while maintaining strict timing synchronization with central control units.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What interface protocol and backplane format does the IS200VAICH1CBR module utilize?\u003c\/p\u003e\n\u003cp\u003eA: The module uses a standard single VMEbus slot architecture designed for direct integration into GE Mark VI Speedtronic control racks.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IS200VAICH1CBR be inserted or extracted while the VME backplane is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. System power to the VME rack must be fully isolated before module installation or removal to avoid backplane pin arc damage or disruption of real-time bus processing.\u003c\/p\u003e\n\u003cp\u003eQ: What safety compliance standards are built into the module architecture?\u003c\/p\u003e\n\u003cp\u003eA: The card is engineered according to IEC 61508 specifications, achieving SIL 3 certification for implementation within safety-critical control loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation\u003c\/strong\u003e: De-energize all primary rack power supplies connected to the VME enclosure before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Safety\u003c\/strong\u003e: Connect an ESD wrist strap to a verified frame ground point prior to touching the circuit card or handling field wiring terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Alignment\u003c\/strong\u003e: Insert the board into the designated VME rack slot, guiding the edge cards carefully along the slot rails until the rear multi-pin DIN connectors meet the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Fastening\u003c\/strong\u003e: Push the module extraction handles inward to seat the edge connectors into the VME backplane, then hand-tighten the top and bottom retaining screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring and Shielding\u003c\/strong\u003e: Route analog signal input cables separately from high-voltage AC lines. Ensure cable shield drain wires are grounded at designated rack grounding bars to minimize electromagnetic interference on analog channels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53266913067317,"sku":"IS200VAICH1CBR","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200VAICH1CBA_2f53e85a-c4bd-4ac6-b324-6e867270bc8c.png?v=1786411369","url":"https:\/\/www.5gplc.com\/products\/is200vaich1cbr-ge-mark-vi-analog-input-vme-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}