{"product_id":"is200trtdh1d-mark-vie-rtd-input-terminal-board-ge-fanuc","title":"IS200TRTDH1D Mark VIe RTD Input Terminal Board | GE Fanuc","description":"\u003cp\u003eConfigured for discrete temperature sensing in Mark VIe control systems, the \u003cstrong\u003eGE IS200TRTDH1D\u003c\/strong\u003e (\u003cstrong\u003eIS200TRTDH1D\u003c\/strong\u003e RTD Input Terminal Board) provides direct physical\/electrical execution. This terminal board accepts 16 three-wire RTD inputs via two barrier-type terminal blocks, providing integrated surge and high-frequency noise suppression to maintain signal integrity before data is processed by the associated PRTD I\/O packs.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TRTDH1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VIe terminal board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on input loop configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e16 x 3-wire RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drives Technical Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TRTDH1D module architecture facilitates simplex operation, interfacing with two PRTD I\/O packs to capture 16 RTD signals. The design incorporates dedicated noise suppression circuitry to mitigate EMI at the input stage, ensuring high-fidelity temperature data conversion. Deterministic communication is managed through I\/O processor integration; users must ensure firmware flash compatibility between the PRTD packs and the central control processor to maintain accurate temperature reporting. I\/O density is scaled through the use of high-density terminal blocks, supporting up to #12 AWG wire gauge, requiring precise adherence to backplane bus communication velocity settings for synchronized data scanning.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200TRTDH1D support triple modular redundancy (TMR)?\u003c\/p\u003e\n\u003cp\u003eA: No. The TRTDH1D is designated for simplex application topologies. It interfaces with two PRTD I\/O packs to provide 16 inputs, whereas TMR configurations require different terminal board hardware variants (e.g., TRTDH1B) capable of fanning inputs to three VRTD boards.\u003c\/p\u003e\n\u003cp\u003eQ: How should double-shielded RTD wiring be terminated on this board?\u003c\/p\u003e\n\u003cp\u003eA: All double-shielded wires must be terminated at the shield terminal strip integrated into the terminal blocks. These strips are connected to the chassis ground, providing a continuous path to drain electromagnetic interference away from the RTD sensing elements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Termination\u003c\/strong\u003e: Land RTD signal wires directly on the barrier-type terminal blocks. Each of the 24-terminal blocks accepts up to #12 AWG wire. Secure terminal blocks using the two provided mounting screws to prevent vibration-induced loosening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding\u003c\/strong\u003e: Utilize double-shielded wire for all RTD connections. Terminate shields at the board's shield terminal strip; ensure end shields are correctly terminated at the field device to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Interfacing\u003c\/strong\u003e: Connect the board to the two PRTD I\/O packs using the dedicated DC-type connectors. Verify that these connections are fully seated and free of debris to maintain reliable signal transmission to the I\/O processors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Mitigation\u003c\/strong\u003e: Ensure the terminal board chassis is bonded to a low-impedance earth ground. Avoid running RTD input cables in parallel with high-voltage AC power lines to prevent signal induction and measurement errors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52948970897717,"sku":"IS200TRTDH1D","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200TRTDH1D.jpg?v=1780299305","url":"https:\/\/www.5gplc.com\/products\/is200trtdh1d-mark-vie-rtd-input-terminal-board-ge-fanuc","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}