{"product_id":"is200tdbth6a-discrete-input-output-terminal-board-ge","title":"IS200TDBTH6A Discrete Input\/Output Terminal Board | GE","description":"\u003cp\u003eConfigured for discrete signal management and relay-based control within Mark VIe architectures, the \u003cstrong\u003eGE IS200TDBTH6A\u003c\/strong\u003e (\u003cstrong\u003eIS200TDBTH6A\u003c\/strong\u003e Discrete Input\/Output Terminal Board) provides direct physical and electrical execution of multi-channel I\/O signal routing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TDBTH6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard terminal board assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 cm x 33.02 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 VDC (Control), 24 VDC (I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O\u003c\/td\u003e\n\u003ctd\u003e24 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Channels\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200TDBTH6A serves as a critical interface node within the Mark VIe control platform, enabling deterministic signal processing for discrete field instrumentation. The board integrates hardware-based input filtering to mitigate noise and provides a rejection capability of 12 V RMS for incoming AC voltage interference. Backplane bus communication velocity is optimized to ensure that state changes across the 24 digital channels and 12 relay outputs are processed within specified scan cycles. Firmware flash compatibility is managed via the host I\/O pack, ensuring that logic transitions remain synchronized with system timing requirements. The board supports I\/O density scaling through its compact surface-mount architecture, allowing for high-density relay control without compromising signal integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IS200TDBTH6A board hot-swappable while the system is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. Replacement of this terminal board must be performed with the control rack de-energized to prevent electrical shorts or backplane communication bus corruption.\u003c\/p\u003e\n\u003cp\u003eQ: Are the 12 relay channels isolated from the 24 digital I\/O channels?\u003c\/p\u003e\n\u003cp\u003eA: The board design requires correct field wiring and shielding practices to ensure isolation between high-power relay switching circuits and low-power digital signal inputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the board using the designated mounting points within the control cabinet. Ensure adequate clearance from high-voltage cabling to prevent inductive noise on the discrete signal paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate all digital I\/O and relay connections to the terminal blocks. Use shielded cabling for long cable runs, and terminate shields at the cabinet grounding bus to suppress common-mode interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Loading:\u003c\/strong\u003e Verify that the current and voltage ratings of the external loads connected to the 12 relay channels do not exceed the board's rated switching capacity. Use suppression diodes when switching inductive loads to extend relay contact life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Maintain the ambient operating temperature between -30 deg C and 65 deg C. Ensure cabinet airflow is sufficient to dissipate heat generated during high-duty relay switching operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Prior to commissioning, confirm the logic mapping for all 24 digital channels and 12 relay outputs via the Mark VIe configuration software. Perform a continuity check on all field wiring before energizing the I\/O circuits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52938041262389,"sku":"IS200TDBTH6A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200TDBTH6A.png?v=1780043315","url":"https:\/\/www.5gplc.com\/products\/is200tdbth6a-discrete-input-output-terminal-board-ge","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}