{"product_id":"is200staih2a-simplex-analog-input-terminal-board-ge","title":"IS200STAIH2A Simplex Analog Input Terminal Board | GE","description":"\u003cp\u003eConfigured for signal termination in Mark VIe control architectures, the \u003cstrong\u003eGE IS200STAIH2A\u003c\/strong\u003e (\u003cstrong\u003eIS200STAIH2A\u003c\/strong\u003e Simplex Analog Input Terminal Board) provides direct physical and electrical execution of multi-channel sensor data routing and 24 VDC loop excitation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200STAIH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard terminal board assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.9 cm x 10.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Excitation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Channels\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Resistance\u003c\/td\u003e\n\u003ctd\u003e15 Ohm (Maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200STAIH2A serves as an interface node within the Mark VIe ecosystem, facilitating standardized signal conditioning between field-mounted instrumentation and system I\/O packs. The board architecture supports deterministic backplane bus communication velocity, ensuring that analog data acquisition remains synchronized with controller scan cycles. Firmware flash compatibility is managed via the host I\/O pack configuration, which defines the scaling and filtering parameters for the 12 input channels. The module supports I\/O density scaling through its compact terminal layout, allowing for high-integrity signal transmission while minimizing signal degradation over field cabling. The surface-mount technology utilized in the PCB construction maintains consistent electrical impedance, supporting precision signal distribution across the simplex architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200STAIH2A support hot-swapping under load?\u003c\/p\u003e\n\u003cp\u003eA: No. Replacement of the terminal board requires the associated I\/O loop to be de-energized to prevent transient currents from damaging the analog input circuitry or the connected field devices.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 24 VDC excitation voltage configurable on a per-channel basis?\u003c\/p\u003e\n\u003cp\u003eA: No. The 24 VDC excitation is common across the designated input channels on the board. Ensure all field instruments connected to these inputs are compatible with the shared excitation voltage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the board within the cabinet using the provided mounting holes. Maintain adequate clearance from high-voltage AC lines to prevent induced noise on the analog signal paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field wiring using the designated terminal blocks. Maintain consistent polarity for all analog loops and ensure that cable shields are grounded at a single, low-impedance point to minimize common-mode noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Resistance:\u003c\/strong\u003e Ensure that the total lead resistance of the field cabling does not exceed 15 Ohm to maintain the accuracy of the signal transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Verify that the cabinet internal temperature remains within the specified range of -30 deg C to +65 deg C. Provide sufficient airflow to prevent heat accumulation around the board's passive and active components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Prior to energization, conduct a point-to-point electrical check to verify wiring integrity and polarity. Use the Mark VIe diagnostic tool to confirm that all 12 analog inputs are correctly registered by the system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52938011738421,"sku":"IS200STAIH2A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200STAIH2A.png?v=1780042589","url":"https:\/\/www.5gplc.com\/products\/is200staih2a-simplex-analog-input-terminal-board-ge","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}