{"product_id":"is200rebfh1bba-ge-mark-vi-ethernet-interface-board","title":"IS200REBFH1BBA | GE | Mark VI Ethernet Interface Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IS200REBFH1BBA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance Ethernet Interface Board within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VI Speedtronic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eturbine control system. This module facilitates deterministic data exchange and provides critical hardware interlocking through its integrated relay outputs. It bridges the gap between the control processor and the plant network, ensuring synchronized communication in complex power generation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGeneral Electric (GE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMark VI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBoard Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet Interface Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24VDC Nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Form C Relay Outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual Redundant Ethernet Ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTCP\/IP, UDP, Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 70°C (-40°F to 158°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH (Non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15.24 cm x 10.16 cm x 2.54 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg (0.66 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual Ethernet port architecture eliminates single points of failure. In the event of a cable break or port malfunction, the board maintains uninterrupted data flow to the Mark VI controller, preventing nuisance turbine trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Output Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board integrates 16 Form C relays into a compact 6.0-inch footprint. This design allows engineers to manage multiple field devices—such as solenoid valves and motor starters—directly through the Ethernet interface, saving significant cabinet space and reducing wiring complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IS200REBFH1BBA operates reliably in extreme temperatures ranging from -40°C to 70°C. This wide thermal window ensures stable performance in unconditioned auxiliary compartments or remote locations subject to seasonal weather extremes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnboard LED indicators provide real-time status updates for power, link activity, and port status. This hardware-level feedback accelerates onsite troubleshooting, allowing technicians to identify network issues without connecting external diagnostic tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this IS200REBFH1BBA unit ship in original factory packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the original GE factory box. Each unit includes a verifiable serial number to ensure full E-E-A-T compliance for your maintenance logs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the board handle power fluctuations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board utilizes a 24VDC nominal input designed to withstand the typical voltage ripples found in industrial power supplies. However, we recommend using a regulated power source to protect the sensitive relay coils and communication chipsets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IS200REBFH1BBA replace older REBF revision boards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe H1BBA revision typically offers backward compatibility with older Mark VI REBF boards. You must verify your specific site configuration in the GE Toolbox software to ensure the firmware matches your existing rack requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the mounting requirements for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe compact 2.54 cm height allows for low-profile mounting within the Mark VI rack. Ensure you maintain the specified humidity levels (5% to 95% non-condensing) to prevent moisture buildup on the Ethernet connectors and relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52525130187061,"sku":"IS200REBFH1BBA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200REBFH1BBA.jpg?v=1775095042","url":"https:\/\/www.5gplc.com\/products\/is200rebfh1bba-ge-mark-vi-ethernet-interface-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}