{"product_id":"is200erscg2a-ge-regulator-static-converter-board","title":"IS200ERSCG2A | GE | Regulator Static Converter Board","description":"\u003cp\u003eConfigured for pulse-width-modulated DC current generation in EX2100 excitation control systems, the \u003cstrong\u003eGE IS200ERSCG2A\u003c\/strong\u003e (\u003cstrong\u003eIS200ERSCG2A\u003c\/strong\u003e Regulator Static Converter Board) provides direct physical and electrical execution of field excitation and discharge control.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ERSCG2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard PCB assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEX2100 standard form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial rated range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-bus dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003eSurface Mount \/ IGBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003ePWM DC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licences\u003c\/h3\u003e\n\u003cp\u003eThe IS200ERSCG2A functions as a high-speed converter interface within the EX2100 architecture, facilitating deterministic control signal exchange with ERIO, ERDD, ERRR, ERRB, and ERBP modules. The board utilizes integrated IGBTs to achieve precise PWM DC output current regulation, while maintaining backplane bus communication velocity compatibility for synchronized excitation control. Firmware flash compatibility is governed by the host excitation controller to ensure timing alignment with turbine operation requirements. I\/O density scaling is managed through modular interconnection, allowing the converter board to operate in both simplex and redundant configurations while maintaining real-time response for field discharge and DC-link bypass relay functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IS200ERSCG2A module capable of hot-swap during excitation system operation?\u003c\/p\u003e\n\u003cp\u003eA: No. Any maintenance or replacement requires the excitation system to be de-energized and verified to a zero-energy state to prevent accidental discharge or IGBT damage.\u003c\/p\u003e\n\u003cp\u003eQ: Can the internal relay bypass be controlled by an external DCS?\u003c\/p\u003e\n\u003cp\u003eA: The relay function is managed by the EX2100 regulator logic. While the system can communicate with a standalone DCS via Modbus, direct relay control is constrained by the board's internal safety and discharge protocols.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the board in the EX2100 control cabinet chassis. Ensure all interface connectors to auxiliary modules (ERIO\/ERDD) are firmly seated to prevent signal jitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Ensure high-current paths for the DC output are terminated using specified cable gauges to minimize voltage drop. Verify that the field discharge circuit is correctly wired to the board's designated terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the board's chassis to the cabinet grounding bus. Proper low-impedance grounding is required to stabilize the PWM reference and mitigate electromagnetic noise from IGBT switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Operate the module within the rated cabinet temperature limits. Ensure that cooling airflow is unobstructed, particularly around the IGBT heatsink assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Prior to startup, perform an impedance check on the DC-link charging resistor bypass circuit. Use the EX2100 diagnostic terminal to confirm software-to-hardware communication and relay functional integrity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52938065314101,"sku":"IS200ERSCG2A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200ERSCG2A.jpg?v=1780044157","url":"https:\/\/www.5gplc.com\/products\/is200erscg2a-ge-regulator-static-converter-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}