{"product_id":"is200erioh1acb-exciter-regulator-main-i-o-board-ge","title":"IS200ERIOH1ACB Exciter Regulator Main I\/O Board | GE","description":"\u003cp\u003eConfigured for signal interfacing in EX2100 excitation control systems, the \u003cstrong\u003eGE IS200ERIOH1ACB\u003c\/strong\u003e (\u003cstrong\u003eIS200ERIOH1ACB\u003c\/strong\u003e Exciter Regulator Main I\/O Board) provides direct physical\/electrical execution of I\/O signal processing between field-level inputs and internal control components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ERIOH1ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctionality\u003c\/td\u003e\n\u003ctd\u003eExciter Regulator Main I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200ERIOH1ACB manages deterministic data exchange between external field signals and the EX2100 control core. The board structure supports both simplex and redundant application architectures, ensuring that signal I\/O remains synchronized with system-level control loops. By functioning as the primary interface, the module preserves the integrity of logic signals by minimizing communication latencies across the backplane bus, enabling the deterministic response required for precise excitation control.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200ERIOH1ACB support hot-swapping within the EX2100 rack?\u003c\/p\u003e\n\u003cp\u003eA: The board design allows for physical removal; however, all power to the associated rack slots must be isolated per site-specific LOTO procedures to prevent electrical damage to the backplane connectors or internal logic circuits during extraction or insertion.\u003c\/p\u003e\n\u003cp\u003eQ: Is this board firmware compatible with older EX2100 system revisions?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility is contingent upon the specific system hardware revision. Refer to the system configuration documentation to ensure the I\/O mapping logic corresponds with the firmware version active on the master regulator.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Control\u003c\/strong\u003e: Ensure the cabinet ambient temperature remains within the specified 0 to 60 deg C range. Inadequate ventilation may trigger thermal derating of the I\/O interface circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding\u003c\/strong\u003e: All incoming field signals must utilize shielded cabling. Terminate the cable shields at the cabinet chassis ground point to ensure high-frequency common-mode noise is diverted away from the logic circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Seating\u003c\/strong\u003e: When installing the board into the EX2100 rack, ensure the backplane connectors are fully engaged. Secure the front-panel captive screws to provide mechanical stability against cabinet-induced vibrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Wiring\u003c\/strong\u003e: Verify that all I\/O connections are verified against the system loop diagrams before applying power to prevent inadvertent short-circuits or signal cross-talk on the regulator inputs.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52949081325877,"sku":"IS200ERIOH1ACB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200ERIOH1ACB.png?v=1780300664","url":"https:\/\/www.5gplc.com\/products\/is200erioh1acb-exciter-regulator-main-i-o-board-ge","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}