{"product_id":"is200ebrgh2a-ge-exciter-bridge-interface-board","title":"IS200EBRGH2A | GE | Exciter Bridge Interface Board","description":"\u003cp\u003eConfigured for thyristor control in EX2100e excitation systems, the \u003cstrong\u003eGE IS200EBRGH2A\u003c\/strong\u003e (\u003cstrong\u003eIS200EBRGH2A\u003c\/strong\u003e Exciter Bridge Interface Board) provides direct physical and electrical execution of gate firing signal processing and bridge feedback monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EBRGH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.2 x 5.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e125 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e42, 52, and 77 mm Thyristor Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eV\/Hz and Field-Oriented Vector Control\u003c\/h3\u003e\n\u003cp\u003eThe IS200EBRGH2A acts as a critical interface layer between the control processor and the power bridge, ensuring precise regulation of excitation current. By facilitating gate command distribution, the board supports the internal algorithms necessary for V\/Hz and field-oriented vector control strategies within the generator excitation loop. The module is engineered to support various thyristor frame sizes (42 mm, 52 mm, and 77 mm), allowing for flexible adaptation to different power bridge architectures. Accurate actuator loop feedback response is maintained through the 0-20 mA analog output stage, ensuring synchronization between the exciter output and generator field requirements. The surface-mount technology utilized on the PCB minimizes parasitic inductance, reducing potential interference in high-speed gate pulse generation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this board be used for thyristor systems outside of the specified 42 mm to 77 mm range?\u003c\/p\u003e\n\u003cp\u003eA: No. The hardware is specifically indexed for compatibility with 42, 52, and 77 mm thyristor architectures. Use with incompatible bridge frame sizes may result in improper firing sequences or gate trigger failure.\u003c\/p\u003e\n\u003cp\u003eQ: Is this board compatible with standard 24 VDC control power?\u003c\/p\u003e\n\u003cp\u003eA: No. The IS200EBRGH2A requires a 125 VDC nominal power supply to operate its gate drive circuitry and bridge interface logic. Verification of the power supply voltage is necessary before energizing the board.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the board within the exciter bridge cabinet. Ensure the mounting standoffs provide adequate clearance from the power bridge busbars to prevent arcing or insulation degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use high-temperature, shielded signal wiring for all gate pulse connections. Maintain strict separation between low-voltage feedback signals and high-power DC\/AC excitation lines to minimize EMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Prior to installation, confirm the thyristor system size matches the configuration of the IS200EBRGH2A. Inspect all connector pins for deformation or oxidation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegration:\u003c\/strong\u003e Verify the 125 VDC supply polarity before connecting the power input. Once seated, perform a cold-loop check using the EX2100e diagnostic software to ensure all gate pulse channels communicate correctly with the main controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the exciter cabinet cooling system is functional. The board is rated for 0 to 60 deg C; exceeding these limits can lead to thermal drift in the analog 0-20 mA feedback loop, causing excitation instability.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52937775481141,"sku":"IS200EBRGH2A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200EBRGH2A.png?v=1780037056","url":"https:\/\/www.5gplc.com\/products\/is200ebrgh2a-ge-exciter-bridge-interface-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}