{"product_id":"is200eacfg2abb-exciter-ac-feedback-board-general-electric","title":"IS200EACFG2ABB Exciter AC Feedback Board | General Electric","description":"\u003cp\u003eConfigured for high-precision analog signal acquisition in Mark VIe excitation control systems, the \u003cstrong\u003eGeneral Electric IS200EACFG2ABB\u003c\/strong\u003e (\u003cstrong\u003eIS200EACFG2ABB\u003c\/strong\u003e Exciter AC Feedback Board) provides direct physical\/electrical execution of voltage monitoring and feedback conditioning.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200EACFG1A\u003c\/td\u003e\n\u003ctd\u003e8 analog inputs\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200EACFG2ABB\u003c\/td\u003e\n\u003ctd\u003e16 analog inputs\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200EACFG3B\u003c\/td\u003e\n\u003ctd\u003e32 analog inputs\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EACFG2ABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eRedundant support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet and Deterministic Network Operations\u003c\/h3\u003e\n\u003cp\u003eThe IS200EACFG2ABB integrates into the Mark VIe control architecture via deterministic network interfaces to ensure synchronized signal polling. The module firmware flash compatibility allows for internal logic updates to maintain alignment with system-wide timing protocols. I\/O density scaling is achieved through the board's 16-channel analog input array, which supports redundant configurations to prevent single-point signal failure. Backplane bus communication velocity is optimized for high-speed data transmission, ensuring that voltage feedback is available for control loop processing within defined deterministic windows.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IS200EACFG2ABB be used in redundant control system configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, this model is specifically engineered to support redundant system configurations, providing higher availability for critical excitation control loops compared to the G1A variant.\u003c\/p\u003e\n\u003cp\u003eQ: Is the input voltage range of the IS200EACFG2ABB compatible with the IS200EACFG3B?\u003c\/p\u003e\n\u003cp\u003eA: No, the IS200EACFG2ABB is designed for 24 V DC input circuits, whereas the IS200EACFG3B is designed for 48 V DC applications. Ensure the field voltage matches the module specification during installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the board within the control cabinet to ensure proper alignment with backplane connectors. Verify that the module is fully seated to maintain reliable backplane communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Wiring:\u003c\/strong\u003e Connect analog input signals to the appropriate terminals. Use shielded, twisted-pair cabling to minimize common-mode noise and maintain the accuracy of the analog signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the module chassis to the system reference ground. Proper grounding is necessary to maintain the integrity of the analog input channels and to prevent ground loop interference in the feedback path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e After installation, utilize the system configuration tool to verify that all 16 analog channels are correctly mapped and reporting valid voltage data to the controller.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52988999696693,"sku":"IS200EACFG2ABB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200EACFG2A_40740088-0ba8-40c1-8f73-7317bf0d2e4e.jpg?v=1781166163","url":"https:\/\/www.5gplc.com\/products\/is200eacfg2abb-exciter-ac-feedback-board-general-electric","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}