{"product_id":"is200aeadh1a-input-output-grid-fork-module-ge","title":"IS200AEADH1A Input\/Output Grid Fork Module | GE","description":"\u003cp\u003eConfigured for signal management and interface routing in Mark VIe Wind and Balance of Plant (BOP) architectures, the \u003cstrong\u003eGE IS200AEADH1A\u003c\/strong\u003e (\u003cstrong\u003eIS200AEADH1A\u003c\/strong\u003e Input\/Output Grid Fork Module) provides direct physical and electrical execution of multi-channel signal distribution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe IS200AEADH1A represents the A-rated primary functional revision of the base IS200AEADH1 grid fork board. This revision is a fixed hardware configuration optimized for specific interface layouts within the Mark VIe control environment.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200AEADH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard PCB assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eRectangular form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial rated range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-bus dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eMulti-pin terminal strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200AEADH1A functions as a signal distribution node, facilitating deterministic communication paths between field instrumentation and the primary control system. The board utilizes high-density terminal strips to maintain backplane bus communication velocity across the I\/O grid. Firmware flash compatibility is strictly defined by the revision level, ensuring that the control logic remains synchronized with the hardware state. The module supports I\/O density scaling by providing versatile connectivity options, including three parallel 12-pin vertical-pin terminal strips, alongside stab-on, plug, and right-angled connectors. This interface diversity allows for integration into non-standard rack assemblies where traditional VME rack mounting may not be applicable.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IS200AEADH1A compatible with standard Mark VIe VME rack assemblies?\u003c\/p\u003e\n\u003cp\u003eA: No. The absence of a front faceplate indicates this module is not designed for insertion into standard 13-slot or 21-slot Mark VIe VME rack architectures. It is intended for specialized mounting via the PCB corner drill holes.\u003c\/p\u003e\n\u003cp\u003eQ: Are the terminal strip pins hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: No. Electrical connections must be de-energized prior to any manipulation of the terminal strips or associated connectors to prevent signal degradation or damage to the backplane communication circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Utilize the pre-drilled corner mounting holes to secure the PCB to a grounded standoff array within the control cabinet. Ensure the mounting orientation allows for adequate clearance from surrounding high-power components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field signals to the vertical-pin terminal strips, plug connectors, or stab-on connectors according to the site-specific wiring schematic. Use appropriate crimping tools to ensure a high-integrity electrical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Maintain shielding continuity for all sensitive analog signal lines. Route cabling through grounded wireways to mitigate electromagnetic interference and potential signal crosstalk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Given the open-board design, maintain a clean, dry, and climate-controlled environment. Avoid direct contact with the PCB surface to prevent damage to the conformal coating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Prior to commissioning, perform a point-to-point continuity test for all I\/O channels. Verify that the interface configuration correctly maps to the corresponding control logic addresses in the Mark VIe master controller.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52937936634165,"sku":"IS200AEADH1ADA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200AEADH1A.png?v=1780040478","url":"https:\/\/www.5gplc.com\/products\/is200aeadh1a-input-output-grid-fork-module-ge","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}