{"product_id":"is200acleh1caa-application-control-layer-module-general-electric","title":"IS200ACLEH1CAA Application Control Layer Module | General Electric","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200ACLEH1CAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200ACLEH1CAA\u003c\/strong\u003e Application Control Layer Module, operates as a dedicated hardware component for microprocessor-based master control and network communication processing within Mark VI Speedtronic control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ACLEH1CAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e23.495 cm H x 10.795 cm W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e125 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Speed\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail (Innovation Series\/EX2100 rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eThe IS200ACLEH1CAA utilizes deterministic network protocols, including Ethernet and ISBus, to execute control logic and data exchange. The module requires specific firmware flash compatibility to support the onboard control block library and online application configuration loading. It functions via the CABP (Control Assembly Backplane Board) or EBKP (Exciter Backplane) interfaces, depending on the host drive or exciter installation. I\/O density scaling and internal Boolean forcing are managed through the core software, which provides high-speed diagnostic monitoring of start\/run permission strings. The 100 MHz processor handles concurrent communication tasks while maintaining scan-time synchronization across the backplane bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What are the physical slot requirements for the IS200ACLEH1CAA?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed to occupy two half-slots within a standard Innovation Series drive or EX2100 exciter board rack.\u003c\/p\u003e\n\u003cp\u003eQ: Is the module compatible with all backplane types?\u003c\/p\u003e\n\u003cp\u003eA: The module connects via a 128-pin P1 connector; it is specifically keyed for use with the Control Assembly Backplane Board (CABP) in drive applications or the Exciter Backplane (EBKP) in excitation systems.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Placement:\u003c\/strong\u003e Secure the module within the designated board rack. Ensure the 128-pin P1 connector is aligned correctly with the backplane header to prevent pin deformation during insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower and Grounding:\u003c\/strong\u003e The unit operates on 125 V dc power input. Ensure the cabinet power distribution is stable and properly bonded to the system common ground to prevent voltage fluctuations that may affect the 100 MHz processor performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Connectivity:\u003c\/strong\u003e If using the optional serial adapter cable (336A4929G1) or serial cable (336A3582P1), verify that the cables are properly shielded and secured to minimize electromagnetic interference (EMI) on the communication lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Check:\u003c\/strong\u003e After initial power-up, observe the status indicators to confirm the module has passed internal self-tests and has successfully established a connection with the host network (Ethernet\/ISBus).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52988829270325,"sku":"IS200ACLEH1CAA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200ACLEH1ACB_60e50c46-feb6-47bb-927e-2f3fd9bbaced.jpg?v=1781162608","url":"https:\/\/www.5gplc.com\/products\/is200acleh1caa-application-control-layer-module-general-electric","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}