{"product_id":"ic695etm001-ge-pacsystems-rx3i-ethernet-module","title":"IC695ETM001 GE PACSystems RX3i Ethernet Module","description":"\u003cp\u003eConfigured for high-speed network communication and deterministic data transport in PACSystems RX3i control platforms, the \u003cstrong\u003eGE IC695ETM001\u003c\/strong\u003e (\u003cstrong\u003eIC695ETM\u003c\/strong\u003e Ethernet Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ETM001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ GE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane Powered (Internal DC Supply Rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2x 10\/100 Mbps Autosensing (8-pin RJ45 Shielded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Port\u003c\/td\u003e\n\u003ctd\u003e1x RS-232 Port (9-pin Female D-sub, 1200 to 115200 bps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Processor Speed\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eSRTP, Modbus TCP (Client\/Server), EGD, SNTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-Swappable\u003c\/td\u003e\n\u003ctd\u003eYes (Supported under power with Firmware 2.51 or higher)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC695ETM001 handles complex TCP\/IP network protocol execution using an onboard 200 MHz Ethernet processor. Offloading SRTP, Modbus TCP, and Ethernet Global Data (EGD) transaction management from the primary controller maintains deterministic backplane bus communication velocity across the RX3i chassis. Onboard non-volatile memory and field-upgradable firmware structures ensure full firmware flash compatibility across PACSystems RX3i CPU revisions, permitting direct integration with compatible backplane units including IC695CHS007, IC695CHS012, and IC695CHS016.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane firmware requirements for hot-swapping the IC695ETM001 module?\u003c\/p\u003e\n\u003cp\u003eA: Module insertion and removal under power (hot-swap) require the system to run firmware revision 2.51 or higher.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IC695ETM001 compatible with all RX3i central processing units?\u003c\/p\u003e\n\u003cp\u003eA: The IC695ETM001 interfaces with standard PACSystems RX3i modules across universal backplanes, with the exception of the CPE400 controller.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic functions are provided by the onboard Station Manager?\u003c\/p\u003e\n\u003cp\u003eA: The Station Manager allows supervisory control, statistic monitoring, event log extraction, and parameter adjustments via either the RS-232 serial port or Ethernet channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the target backplane is an IC695CHS007, CHS012, or CHS016 chassis prior to inserting the module.\u003c\/li\u003e\n\u003cli\u003eAlign the IC695ETM001 module circuit board edge with the card guide rails of any available Universal Backplane slot.\u003c\/li\u003e\n\u003cli\u003ePivot the module firmly into the slot until the backplane connectors seat completely and the top and bottom metal retention clips latch.\u003c\/li\u003e\n\u003cli\u003eGround all Ethernet cable shielding through shielded RJ45 connectors to prevent noise coupling on 10\/100 Mbps lines.\u003c\/li\u003e\n\u003cli\u003eSecure serial cables to the 9-pin female D-connector using terminal retaining screws to maintain connection integrity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53272438407477,"sku":"IC695ETM001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IC695ETM001.png?v=1786514069","url":"https:\/\/www.5gplc.com\/products\/ic695etm001-ge-pacsystems-rx3i-ethernet-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}