{"product_id":"ic200erm001c-ge-versamax-isolated-expansion-receiver-module","title":"IC200ERM001C GE VersaMax Isolated Expansion Receiver Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200ERM001C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200ERM001\u003c\/strong\u003e Isolated Expansion Receiver Module, operates as a dedicated hardware component for multi-rack I\/O bus expansion and signal isolation within GE VersaMax control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ERM001C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (GE Fanuc \/ Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg (0.50 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower sourced via backplane power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Backplane Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Backplane Output Voltage\u003c\/td\u003e\n\u003ctd\u003e3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Connectors\u003c\/td\u003e\n\u003ctd\u003e2 female 26-pin D-shell ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack ID Selection\u003c\/td\u003e\n\u003ctd\u003eOnboard rotary switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLEDs for Power Status and Expansion Bus Status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eFar-left slot on VersaMax expansion rack DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Deterministic Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe IC200ERM001C receives isolated expansion bus signals from an upstream expansion transmitter module (such as the ETM001) via its top 26-pin D-shell port. It rebuilds and routes local backplane voltage levels between 3.3 VDC and 5 VDC to power downstream I\/O and communication modules installed on the expansion rack, optimizing backplane bus communication velocity across long distances.\u003c\/p\u003e\n\u003cp\u003eThe bottom female 26-pin D-shell port enables daisy-chain connections to subsequent expansion racks or accommodates an expansion bus terminator plug on the final node. Full integration into Profinet \/ EtherNet\/IP deterministic network topologies is maintained through the primary controller interface, while strict firmware flash compatibility ensures synchronized scan execution and low-latency protocol passthrough across all extended racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the functional role of the rotary switch located on the IC200ERM001C module?\u003c\/p\u003e\n\u003cp\u003eA: The rotary switch located under the front access door sets the unique hardware address (Rack ID) for the specific expansion rack within the system topology.\u003c\/p\u003e\n\u003cp\u003eQ: How are the two 26-pin female D-shell ports utilized on the expansion receiver module?\u003c\/p\u003e\n\u003cp\u003eA: The top D-shell port receives the expansion cable from the upstream transmitter or preceding receiver, while the bottom port daisy-chains to the next expansion rack or houses a bus termination plug on the final rack.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC200ERM001C module be removed or inserted while the expansion rack power supply is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. All incoming power sources to the expansion rack and primary controller must be de-energized prior to removing or installing the module to prevent electrical damage to the expansion bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Shutdown\u003c\/strong\u003e: De-energize and lock out all power sources feeding the host system and the expansion rack backplane prior to installation or maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Position\u003c\/strong\u003e: Mount the IC200ERM001C module exclusively in the far-left slot position of the VersaMax expansion rack on the 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Configuration\u003c\/strong\u003e: Set the onboard rotary switch to the assigned expansion rack ID number prior to securing the module onto the backplane carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Interconnection\u003c\/strong\u003e: Secure the 26-pin expansion cable from the upstream transmitter into the top D-shell port using integrated thumbscrews. Attach a daisy-chain cable or terminal plug to the bottom D-shell port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e: Wear a grounded anti-static wrist strap attached to the enclosure metallic earth during installation to protect onboard IC logic from static damage.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53267331481909,"sku":"IC200ERM001C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IC200ERM001.jpg?v=1786419313","url":"https:\/\/www.5gplc.com\/products\/ic200erm001c-ge-versamax-isolated-expansion-receiver-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}