{"product_id":"ic200alg620-ge-fanuc-4-channel-16-bit-rtd-analog-input-module","title":"IC200ALG620 | GE FANUC | 4-Channel 16-Bit RTD Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe GE Fanuc VersaMax \u003cstrong\u003eIC200ALG620\u003c\/strong\u003e Analog Input Module is designed for precision resistance and RTD measurement in industrial automation systems. With four input channels, high-resolution conversion, and advanced diagnostics, it ensures accurate temperature and resistance monitoring across a wide range of sensor types.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e \u003cstrong\u003eIC200ALG620\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e GE Fanuc Emerson\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e VersaMax\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e Analog Input Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 0.88 lbs (0.40 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e 4 RTD \/ resistance inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported RTD Sensors\u003c\/strong\u003e Platinum (25, 100, 1000 Ω), Copper (10, 50, 100 Ω), Nickel (100, 120 Ω), Nickel\/Iron (604 Ω)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWiring Types\u003c\/strong\u003e 3-wire and 4-wire RTDs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResistance Input Range\u003c\/strong\u003e 0–500 Ω and 0–3000 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e 16-bit (digital resolution: 15 bits plus sign)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e Approximately 210 ms per channel at 60 Hz, 230 ms at 50 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy at 25°C\u003c\/strong\u003e ±0.15% for resistance and RTD measurements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Sensitivity (0–60°C)\u003c\/strong\u003e ±0.004% of reading, ±1.5 µV per °C referred to input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation (Input to Frame)\u003c\/strong\u003e 1500 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation (Input to Logic)\u003c\/strong\u003e 250 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBus Voltage\u003c\/strong\u003e 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Consumption\u003c\/strong\u003e 5 V output: 125 mA max; 3.3 V output: 125 mA max\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e Open RTD, input short, underrange, overrange, wiring fault, non-volatile memory fault, high\/low alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e 0–60°C ambient\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Lead Resistance\u003c\/strong\u003e 5 Ω per lead\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e 50–60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrecision temperature monitoring in industrial process control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResistance measurement for specialized sensors in manufacturing environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMulti-channel RTD integration for distributed automation systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What types of RTD sensors are supported?\u003c\/strong\u003e  A: The module supports platinum, copper, nickel, and nickel\/iron RTDs across multiple resistance ranges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the resolution of the IC200ALG620?\u003c\/strong\u003e  A: It provides 16-bit resolution, ensuring highly accurate measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the module include diagnostics?\u003c\/strong\u003e  A: Yes, it detects open RTD, short circuits, wiring faults, and provides high\/low alarms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum lead resistance supported?\u003c\/strong\u003e  A: Up to 5 Ω per lead.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparison with Similar Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIC200ALG320\u003c\/strong\u003e: 4-channel current output, 12-bit resolution, fast update rate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIC200ALG326\u003c\/strong\u003e: 8-channel current output, 15-bit resolution, configurable range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIC200ALG430\u003c\/strong\u003e: 4 analog inputs + 2 analog outputs, 12-bit resolution, mixed functionality\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIC200ALG620-JF\u003c\/strong\u003e: 4-channel RTD\/resistance input, 16-bit resolution, advanced diagnostics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52314873692469,"sku":"IC200ALG620","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IC200ALG6201_13bf84a4-851f-4712-aff3-a96c21520dbf.jpg?v=1770706157","url":"https:\/\/www.5gplc.com\/products\/ic200alg620-ge-fanuc-4-channel-16-bit-rtd-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}