{"product_id":"ic200alg260c-ge-versamax-analog-input-module","title":"IC200ALG260C GE VersaMax Analog Input Module","description":"\u003cp\u003eConfigured for single-ended voltage or current signal processing in GE VersaMax control networks, the \u003cstrong\u003eGE IC200ALG260C\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG260\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG260C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (GE Fanuc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane current: 125 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 single-ended channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage or current (unipolar or bipolar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e5.0 ms (Filter response: 5 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e0.4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LED Indicators\u003c\/td\u003e\n\u003ctd\u003eOK, INT PWR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG260C communicates directly across the VersaMax carrier backplane bus, drawing 125 mA at 5 VDC while maintaining high backplane bus communication velocity. The module executes analog-to-digital conversions across 8 single-ended input channels at a scan update rate of 0.4 ms, supporting dynamic field device telemetry routing to the main CPU solver.\u003c\/p\u003e\n\u003cp\u003eFull compatibility with Profinet \/ EtherNet\/IP deterministic networks via network interface units enables predictable multi-node I\/O density scaling. Integrated flash memory maintains firmware flash compatibility to eliminate data conversion skew and enforce precise channel failure diagnostic reporting (Hold Last State or Default Value).\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power draw does the IC200ALG260C module place on the VersaMax backplane 5 VDC bus?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 125 mA at 5 VDC from the backplane logic supply during normal 8-channel acquisition.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC200ALG260C be inserted or removed under power (hot-swapped)?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is permitted only when using an active VersaMax backplane carrier designed for hot insertion; otherwise, baseboard power must be isolated prior to removal.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle signal faults or internal power failures?\u003c\/p\u003e\n\u003cp\u003eA: Diagnostics detect loss of internal power, allowing the module to execute a user-configured fault response: either holding the last valid value or defaulting to a predefined state.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation\u003c\/strong\u003e: Turn off the external 24 VDC loop power supply and backplane rack power prior to mounting or dismounting the module from its carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Protection\u003c\/strong\u003e: Wear a grounded ESD wrist strap connected to the enclosure metal frame when handling the card or setting dip switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Alignment\u003c\/strong\u003e: Align the module keying mechanisms with the VersaMax I\/O carrier slot and press firmly until the locking latch engages fully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Termination\u003c\/strong\u003e: Connect twisted-pair analog signal cable shields to the dedicated carrier ground terminals to minimize noise coupling on 4-20 mA or voltage loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Clearance\u003c\/strong\u003e: Maintain a minimum 50 mm physical separation between low-level analog input wiring and high-voltage AC power lines within the cabinet raceways.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53267321094453,"sku":"IC200ALG260C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IC200ALG260.png?v=1786418881","url":"https:\/\/www.5gplc.com\/products\/ic200alg260c-ge-versamax-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}