{"product_id":"honeywell-tk-rpcxx1-experion-c300-power-supply-module","title":"Honeywell TK-RPCXX1 Experion C300 Power Supply Module","description":"\u003cp\u003eConfigured for primary AC power conversion and multi-rail DC backplane power distribution in Honeywell Experion C300 chassis systems, the \u003cstrong\u003eHoneywell TK-RPCXX1\u003c\/strong\u003e (\u003cstrong\u003eTK-RPCXX1\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution. Operating with an input voltage range of 85 to 265 VAC at 47 to 63 Hz, the module handles up to 110 W input power with a maximum inrush current of 20 A. The unit delivers a total power output of 75 W at 60 deg C, providing regulated DC rails of 1.5 A at 1.2 V, 4 A at 3.3 V, 13 A at 5.1 V, and 2.8 A at 24.0 V directly to the system backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-RPCXX1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.10 kg (2.50 lbs) \/ Shipping: 2.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.4 cm x 13.7 cm x 17.5 cm (5.67 in x 5.39 in x 6.89 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eUp to +60 deg C full rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput: 110 W (110 VA) \/ Max Output: 75 W at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 265 VAC (47 to 63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e20 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Output Current\u003c\/td\u003e\n\u003ctd\u003e1.5 A at 1.2 V \/ 4 A at 3.3 V \/ 13 A at 5.1 V \/ 2.8 A at 24.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Wiring\u003c\/td\u003e\n\u003ctd\u003e#14 AWG (1.4 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnnunciation Connection\u003c\/td\u003e\n\u003ctd\u003eSolid-state relay rated for 120 VAC\/DC at 100 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Cable Model\u003c\/td\u003e\n\u003ctd\u003eTC-RPSC03 (3 ft, optional redundant power supply cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe TK-RPCXX1 integrates power conversion stages that decouple high-voltage AC mains from sensitive analog I\/O conditioning circuits. When supplying power to downstream analog I\/O modules operating on 4-20 mA HART loop protocol networks, the module provides regulated, low-noise 24 VDC bus lines. Internal switching filters suppress ripple and line-side noise, maintaining strict channel-to-channel isolation parameters and preventing potential cross-channel interference across process field loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What size conductor is specified for the AC input power terminal connections on the TK-RPCXX1?\u003c\/p\u003e\n\u003cp\u003eA: The AC input power connections require #14 AWG (1.4 mm) wire to ensure compliance with thermal and current carrying capacity specifications.\u003c\/p\u003e\n\u003cp\u003eQ: How is status fault monitoring handled by the module hardware?\u003c\/p\u003e\n\u003cp\u003eA: The module includes a solid-state relay output connection rated for 120 VAC\/DC at 100 mA maximum, designed for external diagnostic annunciation upon detecting power loss or output fault conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module upright directly above or below the target chassis to allow proper natural convection airflow across cooling vents.\u003c\/li\u003e\n\u003cli\u003eStrip #14 AWG input conductors to specification and torque terminal screws securely to ensure reliable low-resistance electrical contacts.\u003c\/li\u003e\n\u003cli\u003eIf implementing redundant power supply configurations, connect the optional TC-RPSC03 cable assembly between the primary module and backup unit.\u003c\/li\u003e\n\u003cli\u003eVerify overall system safety ground continuity from the module frame ground stud to the main cabinet earth bar before applying AC line voltage.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53626078921013,"sku":"TK-RPCXX1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TK-RPCXX11_Cocoai.png?v=1790059024","url":"https:\/\/www.5gplc.com\/products\/honeywell-tk-rpcxx1-experion-c300-power-supply-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}