{"product_id":"honeywell-tk-oav081-analog-output-module","title":"Honeywell TK-OAV081 Analog Output Module","description":"\u003cp\u003eConfigured for multi-channel voltage and current loop drive in Experion PKS platforms, the \u003cstrong\u003eHoneywell TK-OAV081\u003c\/strong\u003e (\u003cstrong\u003eTC-OAV081\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-OAV081 (TC-OAV081)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg (Shipping Weight: 2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Experion C200\/C300 module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.9 W maximum power dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e8 channels (0 to 21 mA or +\/-10.4 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Capability\u003c\/td\u003e\n\u003ctd\u003eGreater than 2000 ohm (Voltage) \/ 0-750 ohm (Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003eTC-TBNH 20-position terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe TK-OAV081 processes 8 discrete channels with a 25 ms module update cycle and an output settling time under 2 ms to 95% of final value with resistive loads. Tested to 2550 VDC user-to-system isolation, the unit isolates backplane digital processing logic from external field transient surges and potential ground loops. Built-in electronic current limiting caps loop outputs at 21 mA or less to maintain continuous short-circuit protection, delivering a calibrated accuracy better than 0.05% of range at 25 deg C across standard 4-20 mA loop spans.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the output circuit maintain stability during sustained field terminal overvoltage exposure?\u003c\/p\u003e\n\u003cp\u003eA: Each field channel incorporates output overvoltage protection rated for continuous 24 VAC\/VDC at room temperature, preventing catastrophic internal component failures during inadvertent wiring cross-connections.\u003c\/p\u003e\n\u003cp\u003eQ: What happens if an output channel experiences a sustained short circuit during operation?\u003c\/p\u003e\n\u003cp\u003eA: Internal active limiting hardware caps the fault current to 21 mA or less, allowing the remaining operational channels to continue driving field loads without thermal degradation or bus interference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Header Engagement\u003c\/strong\u003e: Securely latch the 20-position TC-TBNH terminal block onto the front module connector before energizing field loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Drain Grounding\u003c\/strong\u003e: Ground individual signal cable drain wires at the cabinet single-point ground bus to maintain less than 2.0% signal deviation under 10 V\/m RF field conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvective Air Clearance\u003c\/strong\u003e: Preserve a 50 mm vertical clearance above and below the module rack assembly to support passive airflow and stay within thermal dissipation boundaries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Retention\u003c\/strong\u003e: Ensure both upper and lower mounting retention clips lock firmly onto the enclosure DIN-rail to prevent contact erosion from machinery vibration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67653579833653,"sku":"TК-OAV081","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/T_-OAV081.png?v=1791432234","url":"https:\/\/www.5gplc.com\/products\/honeywell-tk-oav081-analog-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}