{"product_id":"honeywell-pw6k1r2-pw-6000-series-dual-reader-module","title":"Honeywell PW6K1R2 PW-6000 Series Dual Reader Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell PW6K1R2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePW6K1R2\u003c\/strong\u003e Dual Reader Module, operates as a dedicated hardware component for credential verification and direct door access hardware execution within PW-6000 Series \/ ProWatch platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePW6K1R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.13 lbs (0.06 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PW-6000 Series Module Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via controller backplane \/ 12 VDC input bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Processor\u003c\/td\u003e\n\u003ctd\u003e32-bit onboard processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReader Ports\u003c\/td\u003e\n\u003ctd\u003e2 ports (Wiegand protocol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eRS485 bus, TCP\/IP for remote monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Bus Length\u003c\/td\u003e\n\u003ctd\u003e4,000 ft \/ 1,250 m per RS485 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Density\u003c\/td\u003e\n\u003ctd\u003eUp to 32 I\/O or reader modules per PW6K1IC controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Compatibility\u003c\/td\u003e\n\u003ctd\u003ePW5K2ENC1, PW5K2ENC2, PW5K2ENC5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Configurations\u003c\/td\u003e\n\u003ctd\u003eNormally Open\/Closed, supervised, non-supervised inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eEngineered for field instrumentation and access control interface integration within Honeywell system architectures, the module incorporates isolated communication paths and dedicated input supervision. Galvanic channel-to-channel isolation prevents electrical noise and ground potential loops from corrupting Wiegand data lines, RS485 bus communications, or auxiliary analog feedback signals. The onboard 32-bit processor executes real-time access decision logic locally, sustaining operational security states even during temporary host network disruptions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many Wiegand card readers can be connected directly to a single PW6K1R2 module?\u003c\/p\u003e\n\u003cp\u003eA: The module contains 2 dedicated Wiegand reader ports for direct wiring of standard card access readers.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum distance supported for the RS485 communication bus?\u003c\/p\u003e\n\u003cp\u003eA: The RS485 communication bus supports a maximum length of 4,000 ft (1,250 m) per port.\u003c\/p\u003e\n\u003cp\u003eQ: Are cabinet tamper and power supply diagnostics monitored by the hardware?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module features dedicated physical input channels specifically designated for cabinet tamper switches and auxiliary power status monitoring.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the board securely using flat or tile mounting configurations inside approved PW5K2ENC1, PW5K2ENC2, or PW5K2ENC5 enclosures.\u003c\/li\u003e\n\u003cli\u003eWire reader inputs using shielded twisted-pair cables, grounding the shield drain wire at the enclosure grounding point only.\u003c\/li\u003e\n\u003cli\u003eTerminate the RS485 communication line using standard end-of-line resistors when the module is installed as the terminal node on the bus.\u003c\/li\u003e\n\u003cli\u003eEnsure proper power polarity and ground connections to prevent voltage surges across supervised input loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53631345688885,"sku":"PW6K1R2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PW6K1R2_Cocoai.png?v=1790135434","url":"https:\/\/www.5gplc.com\/products\/honeywell-pw6k1r2-pw-6000-series-dual-reader-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}