{"product_id":"honeywell-mu-tdor22-51304427-100-digital-output-relay-module-16-channel","title":"Honeywell MU-TDOR22 51304427-100 | Digital Output Relay Module 16-Channel","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TDOR22 (51304427-100)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital output assembly designed for the Honeywell Process Manager (PM), Advanced Process Manager (APM), and High-Performance Process Manager (HPM) families. This module provides 16 isolated channels, each capable of being independently configured via physical jumpers to operate as either Form A (Normally Open) or Form B (Normally Closed) contacts.\u003c\/p\u003e\n\u003cp\u003eUtilizing premium silver alloy contact material, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TDOR22 (51304427-100)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures long-term switching reliability in demanding industrial control loops. The hardware architecture is specifically engineered for high-voltage isolation, protecting the system backbone from field-side transients.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Relay Digital Output (TDC 3000 \/ Experion PKS compatible)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e: 16 fully isolated outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e: Jumper-selectable Form A (SPST-NO) or Form B (SPST-NC) per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e: Silver Alloy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDielectric Isolation\u003c\/strong\u003e: 1500 Vac rms or ±1500 Vdc (Channel-to-Channel and Channel-to-Common)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAC Load Rating\u003c\/strong\u003e: 265 Vac (rms) maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Load Rating\u003c\/strong\u003e: 140 Vdc maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Capacity (Resistive)\u003c\/strong\u003e: 2.5 A @ 240 Vac \/ 2 A @ 30 Vdc \/ 0.5 A @ 125 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHorsepower Rating\u003c\/strong\u003e: 1\/8 HP per output channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Switching Requirement\u003c\/strong\u003e: 100 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TDOR22 (51304427-100)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically deployed for heavy-duty switching tasks where standard electronic outputs lack sufficient current capacity or isolation. Common use cases include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInterfacing with motor starters and solenoid valves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrating non-standard field voltage signals into the DCS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency shutdown (ESD) auxiliary signaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePilot light and alarm annunciator control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the contact logic changed from NO to NC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe logic for each channel on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TDOR22 (51304427-100)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis determined by the physical position of the onboard jumpers. This must be configured prior to installation to match the field device requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support inductive loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is rated for 1\/8 HP; however, for highly inductive DC loads, external surge suppression (such as a flyback diode) is recommended to maximize the lifespan of the silver alloy contacts.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52467008700725,"sku":"MU-TDOR22 51304427-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/MU-TDOD1251304423-100_94566bf5-0a79-450f-aff1-02b34b63d1b3.jpg?v=1774237536","url":"https:\/\/www.5gplc.com\/products\/honeywell-mu-tdor22-51304427-100-digital-output-relay-module-16-channel","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}