{"product_id":"honeywell-fta-t-02-fail-safe-digital-output-module","title":"Honeywell FTA-T-02 Fail-Safe Digital Output Module","description":"\u003cp\u003eConfigured for high-density digital output distribution in control system architectures, the \u003cstrong\u003eHoneywell FTA-T-02\u003c\/strong\u003e (\u003cstrong\u003eFTA-T-02\u003c\/strong\u003e Fail-Safe Digital Output Module) provides direct physical execution of signal routing for 24 discrete channels. The hardware manages outputs across six independent groups, interfacing system controller logic with field-side actuators while maintaining operational safety requirements.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFTA-T-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.5 x 7.0 x 5.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 24\/48\/60 VDC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e24 (6 groups of 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e2 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Voltage\u003c\/td\u003e\n\u003ctd\u003e36 VAC\/50 VDC (Cat 3); 125 VAC\/150 VDC (Cat 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe FTA-T-02 assembly maintains channel-to-channel isolation by segregating the 24 output channels into six distinct groups. This compartmentalization prevents electrical faults or surge currents occurring in a single field loop from propagating to adjacent output channels or the backplane communication bus. By adhering to IEC 1010 standards for overvoltage categories, the module ensures signal integrity and prevents common-mode noise from disrupting logic execution. The design supports the use of 4-20 mA HART loop protocol connectivity for downstream field devices where applicable, ensuring consistent data transition and feedback monitoring across the control network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support hot-swapping on a live backplane?\u003c\/p\u003e\n\u003cp\u003eA: The FTA-T-02 is designed for fixed installation. Hot-swapping is not supported; removal or installation during system operation may induce transient voltages on the output bus, which can result in unintended state transitions or damage to the output buffers.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific tightening requirements for the screw terminal connections?\u003c\/p\u003e\n\u003cp\u003eA: Yes, to ensure reliable electrical contact and prevent terminal overheating, terminal screws must be tightened to exactly 0.5 Nm. Excessive torque can cause damage to the terminal block threads, while insufficient torque may result in high-resistance connections or intermittent signal faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSecure the unit onto a TS32 or TS35 x 7.5 DIN EN rail; ensure at least 14.6 cm of rail length is available to accommodate the module dimensions.\u003c\/li\u003e\n\u003cli\u003eEnsure all power supplies are de-energized before beginning field wiring to prevent accidental shorting of the output channels.\u003c\/li\u003e\n\u003cli\u003ePrepare field wiring by stripping insulation to 0.7 cm and ensuring the conductor does not exceed 0.25 cm squared (AWG 14).\u003c\/li\u003e\n\u003cli\u003eTerminate wires to the screw terminals, ensuring each connection is torqued to 0.5 Nm.\u003c\/li\u003e\n\u003cli\u003eBond the DIN rail assembly to the cabinet earth ground to provide a low-impedance path for electromagnetic interference (EMI) protection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52975899377973,"sku":"FTA-T-02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FTA-T-02.png?v=1780988033","url":"https:\/\/www.5gplc.com\/products\/honeywell-fta-t-02-fail-safe-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}