{"product_id":"honeywell-fs-tsro-0824-digital-output-field-termination-assembly","title":"Honeywell FS-TSRO-0824 Digital Output Field Termination Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-TSRO-0824\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFS-TSRO-0824\u003c\/strong\u003e Digital Output Field Termination Assembly, operates as a dedicated hardware component for switching high-power discrete field loads and providing physical contact isolation within Safety Manager and FSC systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-TSRO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNetherlands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e300 x 70 x 60 mm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypically 40 mA at 24 VDC per active channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Class\u003c\/td\u003e\n\u003ctd\u003eAK1-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, UL, TÜV approvals pending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input Voltage\u003c\/td\u003e\n\u003ctd\u003e36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Pick-up Voltage\u003c\/td\u003e\n\u003ctd\u003e19.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 relay contact outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC \/ 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Current\u003c\/td\u003e\n\u003ctd\u003e5 A (fused per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Output Current\u003c\/td\u003e\n\u003ctd\u003e1 mA at 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Load\u003c\/td\u003e\n\u003ctd\u003e1250 VA \/ 150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation and Safety Loop Contact Execution\u003c\/h3\u003e\n\u003cp\u003eThe FS-TSRO-0824 provides channel-to-channel and field-to-logic galvanic isolation through heavy-duty electromechanical relays. Configured for Safety Integrity Level (SIL) applications up to safety class AK1-6, the module provides isolated dry-contact outputs capable of handling up to 250 VAC\/VDC switching loads. The discrete relay driver circuit enforces predictable contact open\/close states under system fault conditions, preventing back-EMF voltage transients from entering the central controller backplane or safety logic solver cards. Integrated individual fuses protect each output channel against external short-circuit overcurrent events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the minimum switching threshold required to maintain clean contact closure across the relay outputs?\u003c\/p\u003e\n\u003cp\u003eA: The minimum output load specification is 1 mA at 5 V. Operating below this current and voltage limit may lead to inconsistent contact resistance due to lack of wetting current.\u003c\/p\u003e\n\u003cp\u003eQ: How is individual output channel circuit protection handled on the assembly?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 8 output channels features a dedicated inline fuse rated to interrupt overcurrent conditions above 5 A, isolating external field shorts before causing damage to the internal trace geometry or relay contacts.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum permitted input voltage to ensure reliable coil actuation without thermal overstress?\u003c\/p\u003e\n\u003cp\u003eA: While the nominal logic input drive voltage is 24 VDC with a pick-up voltage threshold of 19.2 VDC, the maximum continuous allowable input voltage is 36 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the assembly securely on standard TS35 DIN rail inside an IP54 or better grounded metallic enclosure to ensure adequate mechanical stability and environmental protection.\u003c\/li\u003e\n\u003cli\u003eRoute high-voltage AC\/DC field wiring away from low-voltage DC logic signaling lines in separate wiring ducts to avoid electromagnetic interference and inductive coupling.\u003c\/li\u003e\n\u003cli\u003eTorque all field screw-terminal connections to recommended manufacturer specifications (typically 0.5 to 0.6 Nm) to ensure vibration-resistant electrical continuity.\u003c\/li\u003e\n\u003cli\u003eVerify that field load currents do not exceed 5 A continuous per channel and that inductive loads are fitted with external suppression devices (snubbers for AC, flyback diodes for DC) across the field load terminals.\u003c\/li\u003e\n\u003cli\u003eConnect cabinet protective earth (PE) grounding wire directly to the module earth stud prior to applying power or field load voltage.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53514048405813,"sku":"FS-TSRO-0824","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FS-TSRO-0824_Cocoai.png?v=1788916218","url":"https:\/\/www.5gplc.com\/products\/honeywell-fs-tsro-0824-digital-output-field-termination-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}