{"product_id":"honeywell-fs-fanwr-24r-safety-manager-fan-tray-assembly","title":"Honeywell FS-FANWR-24R Safety Manager Fan Tray Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FS-FANWR-24R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(also identified as FC-FANWR-24R) functions as the primary forced-air cooling solution for the Honeywell Safety Manager (FSC\/SM) chassis. This specialized fan tray assembly maintains the thermal equilibrium of high-density processor and I\/O racks, preventing localized heat buildup that can lead to logic solver degradation or premature component failure. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estock, ensuring your SIL-rated safety systems operate within certified temperature parameters.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe FS-FANWR-24R features a robust mechanical design optimized for continuous 24\/7 operation in critical infrastructure:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFS-FANWR-24R \/ FC-FANWR-24R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCooling Fan Tray Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e39.1 cm x 14.1 cm x 6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.44 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Year\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Safety Manager Rack Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTargeted Heat Extraction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FS-FANWR-24R utilizes high-static pressure fans to force air through densely packed I\/O cards. This airflow removes stagnant heat pockets from the center of the chassis, extending the Mean Time Between Failures (MTBF) of adjacent processors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Vibration Operation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell engineers this tray with precision-balanced fan blades and vibration-dampening mounts. This design prevents mechanical harmonics from transferring to the backplane, protecting sensitive electronic connectors from fretting corrosion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlim Profile Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 6cm height allows for easy integration into standard safety cabinets without sacrificing valuable rail space. It slides directly into the dedicated cooling slot, aligning perfectly with the system's intended convection paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Cooling Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn high-availability architectures, the FS-FANWR-24R integrates with the system's power distribution to provide continuous ventilation. Even in redundant configurations, this unit ensures that thermal limits remain within safe thresholds during peak processing loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit features a standardized interface that allows for rapid replacement. This minimizes \"Time-to-Repair\" during scheduled maintenance intervals, keeping the Safety Instrumented System (SIS) fully protected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the FS-FANWR-24R require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The fan tray draws its 24VDC power directly from the Safety Manager backplane or power distribution bus once you slide it into the chassis. This ensures the cooling system starts automatically whenever the safety rack energizes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the consequences of operating a Safety Manager rack without this fan tray?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOperating without forced ventilation significantly increases the internal temperature of processor modules. High heat can trigger thermal alarms in the diagnostic software and may eventually cause an unscheduled shutdown of the safety loop to protect hardware from permanent damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I inspect the FS-FANWR-24R?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe recommend a visual inspection every six months to check for dust accumulation. Clear airflow remains critical for cooling efficiency. Replacing aged fan units with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits every 3–5 years prevents bearing failure and maintains optimal RPM levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with both FSC and Safety Manager systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FS-FANWR-24R fits the standardized chassis dimensions used across the Honeywell Fail Safe Control (FSC) and Safety Manager product lines, providing a universal cooling solution for these legacy and modern platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52852787773749,"sku":"FS-FANWR-24R","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FS-FANWR-24R.png?v=1778313252","url":"https:\/\/www.5gplc.com\/products\/honeywell-fs-fanwr-24r-safety-manager-fan-tray-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}