{"product_id":"honeywell-fc-sdo-0824-cc-v1-4-digital-output-module","title":"Honeywell FC-SDO-0824 CC V1.4 Digital Output Module","description":"\u003cp\u003eConfigured for discrete trip signal execution and output loop switching in Safety Manager platforms, the \u003cstrong\u003eHoneywell FC-SDO-0824 CC V1.4\u003c\/strong\u003e (\u003cstrong\u003eFC-SDO-0824\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. It delivers controlled 24 VDC driving signals to final safety elements across field termination sub-assemblies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-SDO-0824 CC V1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 cm x 12.7 cm x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane internal bus draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 safe digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (CC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Signal Conditioning Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe FC-SDO-0824 CC V1.4 incorporates channel-to-channel isolation and physical galvanic separation to protect internal logic solvers against field-side voltage transients. Factory conformal coating guards electronic circuits against atmospheric humidity and airborne contaminants. The module routes discrete output signals without interfering with adjacent 4-20 mA HART loop protocol field wiring, providing hardware-level fault suppression across all output channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary operational function of the \"CC\" specification suffix on the FC-SDO-0824 CC V1.4?\u003c\/p\u003e\n\u003cp\u003eA: The \"CC\" designation indicates Factory Conformal Coating, which protects surface-mounted electronics from environmental moisture, corrosive vapors, and conductive dust accumulation inside industrial control cabinets.\u003c\/p\u003e\n\u003cp\u003eQ: Can the FC-SDO-0824 CC V1.4 output channels be replaced under live system power?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping the module is permitted provided the carrier rack retains backplane power stability and standard electro-static discharge (ESD) guidelines are followed during physical extraction.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Alignment\u003c\/strong\u003e: Align the module housing with the card guide rails of the designated rack slot. Slide the assembly inward until the backplane contacts seat fully, then lock the retaining latches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocols\u003c\/strong\u003e: Connect field signal cable shields directly to the master enclosure earthing bar using low-impedance grounding straps to minimize high-frequency noise injection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Clearance\u003c\/strong\u003e: Maintain physical separation of at least 30 cm between 24 VDC discrete output wiring and high-voltage AC distribution conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Ventilation\u003c\/strong\u003e: Ensure a minimum vertical clearance of 50 mm above and below the rack chassis to facilitate convective air circulation across the enclosure.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53494037643573,"sku":"FC-SDO-0824 CC V1.4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FC-SDOL-0424_0d278a80-f54c-425e-8fc4-965da7f792d4.jpg?v=1788835142","url":"https:\/\/www.5gplc.com\/products\/honeywell-fc-sdo-0824-cc-v1-4-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}