{"product_id":"honeywell-fc-iobus-cpio2-i-o-bus-extension-interface-module","title":"Honeywell FC-IOBUS-CPIO2 I\/O Bus Extension Interface Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-IOBUS-CPIO2 (Part No. FC-IOBUS-CPIO2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a critical communication bridge within the Honeywell Safety Manager architecture. This I\/O Bus Extension Module is engineered to extend the reach of the proprietary safety bus, allowing for the integration of remote I\/O chassis while maintaining high-speed, deterministic data exchange. It facilitates the transparent flow of data between the central controller and distributed field modules, ensuring that safety-critical timing requirements are met across extended distances.\u003c\/p\u003e\n\u003cp\u003eDesigned with industrial-grade EMI\/RFI shielding, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-IOBUS-CPIO2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes ferrite-enhanced signal processing to maintain communication integrity in environments with high electrical noise. It supports flexible mounting configurations and wide-range temperature operation, making it suitable for both control room and remote cabinet installations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications \u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: I\/O Bus Extension and Signal Bridging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e: 24V DC (±10% tolerance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e: 2 Configurable channels for versatile signal handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Inputs\u003c\/strong\u003e: Analog (4-20mA), Digital, and Thermocouple via interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Output Range\u003c\/strong\u003e: 0 to 21 mA (supporting over-range diagnostics)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e: RS485 physical layer; supports I\/O Bus-CX\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e: Modbus and Ethernet\/IP (utilizing external converters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e: 100 kHz high-speed data acquisition capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e: 3.5 W maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Range\u003c\/strong\u003e: -40°C to +85°C \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Construction\u003c\/strong\u003e: 120 mm x 100 mm x 60 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 3.7 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e: Support for standard 35mm DIN rail or direct panel mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-IOBUS-CPIO2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily utilized in large-scale Distributed Control Systems (DCS) and Safety Instrumented Systems (SIS). It is the preferred solution for interconnecting safety cabinets located in different process areas, such as connecting an Emergency Shutdown (ESD) main controller to remote fire and gas detection racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering FAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the FC-IOBUS-CPIO2 handle electrical interference?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe module is equipped with ferrite-core enhanced filtering, which provides superior suppression of high-frequency electromagnetic interference (EMI) and radio frequency interference (RFI) common in heavy industrial switchgear environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eWhile the I\/O bus allows for modularity, it is recommended to follow Honeywell Safety Manager hot-swap procedures to ensure the safety loop remains intact during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52427683365173,"sku":"FC-IOBUS-CPIO2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FC-IOBUS-CPIO2.jpg?v=1773217676","url":"https:\/\/www.5gplc.com\/products\/honeywell-fc-iobus-cpio2-i-o-bus-extension-interface-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}