{"product_id":"honeywell-fc-bn-1608-sensor-converter-module","title":"Honeywell FC-BN-1608 Sensor Converter Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-BN-1608\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-BN-1608\u003c\/strong\u003e Sensor Converter Module, operates as a dedicated hardware component for field sensor signal conditioning and backplane bus conversion within Honeywell Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-BN-1608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNetherlands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Safety Manager single-slot card size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC backplane bus supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSensor Signal Converter Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16-channel sensor interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ FSC System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conversion\u003c\/td\u003e\n\u003ctd\u003eField sensor inputs to internal bus logic level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003eSystem-to-field and channel-to-channel isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Sensor Loop Integrity\u003c\/h3\u003e\n\u003cp\u003eThe FC-BN-1608 sensor converter module processes 16 field sensor channels, converting field-level input signals into digital logic signals for processing by central safety logic solvers. High-grade galvanic isolation circuitry shields backplane communications from field-side voltage surges, common-mode ground loops, and electrical noise. By preserving channel-to-channel isolation, the card prevents field faults on individual sensor circuits from impacting adjacent process channels, supporting clean signal acquisition for standard 4-20 mA HART loop protocol transmitters and discrete sensing devices.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the FC-BN-1608 protect system logic cards against high-voltage field spikes?\u003c\/p\u003e\n\u003cp\u003eA: Integrated optocouplers and galvanic isolation barriers isolate the 16 field sensor inputs from the backplane, suppressing common-mode transients up to 1.5 kV.\u003c\/p\u003e\n\u003cp\u003eQ: Is live hot-swapping supported for the FC-BN-1608 module in an active Safety Manager rack?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is permitted provided the slot is part of a redundant pair or safety bypass overrides are active according to site plant safety procedures.\u003c\/p\u003e\n\u003cp\u003eQ: What power rail supplies the internal logic and channel conditioning circuits?\u003c\/p\u003e\n\u003cp\u003eA: The module draws power directly from the 24 VDC rack power distribution backplane via its rear edge connector.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify system bypass or power-down conditions before inserting the module into its designated rack slot.\u003c\/li\u003e\n\u003cli\u003eAlign the top and bottom edge card guides with the subrack rails and push the module firmly into the backplane socket.\u003c\/li\u003e\n\u003cli\u003eTighten the top and bottom module retaining screws to establish low-impedance grounding contact with the subrack chassis frame.\u003c\/li\u003e\n\u003cli\u003eRoute field sensor cabling through segregated low-voltage instrument wireways away from AC power lines and inverter circuits.\u003c\/li\u003e\n\u003cli\u003eConnect cable shield drains directly to the cabinet instrumentation earth bus bar to ensure effective noise rejection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53515723768117,"sku":"FS-BN-1608","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FS-BN-1608.png?v=1788921490","url":"https:\/\/www.5gplc.com\/products\/honeywell-fc-bn-1608-sensor-converter-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}