{"product_id":"honeywell-experion-pks-i-o-module-51454416-100","title":"Honeywell Experion PKS I\/O Module | 51454416-100","description":"\u003cp\u003eConfigured for high-speed Ethernet routing and signal handling in DCS \/ Experion PKS platforms, the \u003cstrong\u003eHoneywell 51454416-100\u003c\/strong\u003e (\u003cstrong\u003e51454416-100\u003c\/strong\u003e I\/O Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51454416-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7 cm x 14 cm x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Module \/ Ethernet Router Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100\/1000BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Protection\u003c\/td\u003e\n\u003ctd\u003e1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e+\/- 2 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Capacity\u003c\/td\u003e\n\u003ctd\u003e32 simultaneous Modbus TCP connections, 2048 MAC table entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Network Protocol Processing\u003c\/h3\u003e\n\u003cp\u003eThe module integrates 1500 V AC galvanic isolation and +\/- 2 kV surge protection across all network channels to isolate field-side electrical transients from the controller backplane. Operating over a 24 VDC supply, its dual Gigabit Ethernet interface processes 32 simultaneous Modbus TCP connections with signal routing latency under 5 us. The hardware layer enforces channel-to-channel isolation and deterministic data execution within Experion PKS network structures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What level of electrical isolation does the network interface provide?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates 1500 V AC isolation protection along with +\/- 2 kV surge protection on its dual 10\/100\/1000BASE-T Ethernet channels.\u003c\/p\u003e\n\u003cp\u003eQ: How many simultaneous field network connections can the module maintain?\u003c\/p\u003e\n\u003cp\u003eA: The internal stack supports up to 32 simultaneous Modbus TCP connections and maintains a MAC address table capacity of 2048 entries.\u003c\/p\u003e\n\u003cp\u003eQ: What are the input power constraints for the 51454416-100 unit?\u003c\/p\u003e\n\u003cp\u003eA: The unit requires a regulated 24 VDC power source and operates with a nominal power consumption of 4.8 W.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the primary 24 VDC power supply is isolated and de-energized prior to hardware mounting.\u003c\/li\u003e\n\u003cli\u003eSecure the module housing to the panel rack or mounting rail using standard hardware, maintaining clearance for air dissipation across the -40 to +70 deg C operating range.\u003c\/li\u003e\n\u003cli\u003eConnect category 5e\/6 industrial Ethernet cables to the dual RJ-45 ports, ensuring connector retention clips engage completely.\u003c\/li\u003e\n\u003cli\u003eFasten the frame ground terminal to the main panel enclosure ground bar to optimize surge protection up to +\/- 2 kV.\u003c\/li\u003e\n\u003cli\u003eApply 24 VDC input power and inspect hardware LED indicators to confirm network Link\/Activity status on active channels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53594667876661,"sku":"51454416-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CC-PDOB0151405043-1761_Cocoai_d4ac9dd2-a062-496d-ba80-08c3700ab96a.png?v=1789528057","url":"https:\/\/www.5gplc.com\/products\/honeywell-experion-pks-i-o-module-51454416-100","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}