{"product_id":"honeywell-dc-tdil11-experion-pks-digital-input-iota-module","title":"Honeywell DC-TDIL11 Experion PKS Digital Input IOTA Module","description":"\u003cp\u003eConfigured for 24 VDC discrete signal conditioning and field acquisition in Honeywell Experion PKS controller networks, the \u003cstrong\u003eHoneywell DC-TDIL11\u003c\/strong\u003e (\u003cstrong\u003eDC-TDIL11\u003c\/strong\u003e Digital Input IOTA) provides direct physical\/electrical execution. The assembly routes 32 discrete channel inputs directly across a redundant Input Output Termination Assembly (IOTA) backplane connector interface. Internal circuitry supports field-selectable internal or external DI sense power, establishing logical contact state evaluation and current-limited signaling across C300 controller networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDC-TDIL11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.1 cm x 12.7 cm x 3.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 discrete digital input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eNon-isolated, field-selectable internal\/external sense power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIntegrated fuse protection for 24 VDC power rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe DC-TDIL11 IOTA board utilizes channel-to-channel isolation techniques on its power supply rails and backplane communication channels to protect system logic from field-side electrical transients. Integrated fuse barriers safeguard the shared 24 VDC field distribution loops against short-circuit conditions, while common-mode signal filtering suppresses noise propagation across adjacent channels during simultaneous contact state switching.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the DC-TDIL11 module be inserted into an active redundant IOTA assembly without powering down the C300 controller node?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The IOTA hardware architecture supports online module replacement, provided the redundant IOTA channel remains active during card swap operations.\u003c\/p\u003e\n\u003cp\u003eQ: How is field sense power configured for the 32 input channels on the DC-TDIL11 IOTA?\u003c\/p\u003e\n\u003cp\u003eA: Sense power source selection between internal 24 VDC bus supply and external field power is accomplished via physical hardware jumper links on the IOTA board.\u003c\/p\u003e\n\u003cp\u003eQ: What protection prevents overcurrent faults from spreading across the 24 VDC sense power rails?\u003c\/p\u003e\n\u003cp\u003eA: Integrated fast-acting fuse protection isolates the 24 VDC field supply lines in the event of an external field wiring short circuit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect main power from field supply terminals before configuring hardware sense power jumpers on the IOTA.\u003c\/li\u003e\n\u003cli\u003eAlign the module card connectors with the mating IOTA base assembly and press firmly until both locking levers fully engage.\u003c\/li\u003e\n\u003cli\u003eVerify that all 24 VDC field wiring terminations are connected according to correct polarity guidelines.\u003c\/li\u003e\n\u003cli\u003eRoute 24 VDC discrete field input cables separately from high-voltage AC conductors to prevent capacitive coupling and switching noise.\u003c\/li\u003e\n\u003cli\u003eSecure all field wiring shield drain wires to the main system grounding bar with a short, low-impedance connection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53621001650485,"sku":"DC-TDIL11","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DC-TDIL11_Cocoai.png?v=1789969830","url":"https:\/\/www.5gplc.com\/products\/honeywell-dc-tdil11-experion-pks-digital-input-iota-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}