{"product_id":"honeywell-cp-dynb-aio-analog-i-o-base-board-module","title":"Honeywell CP-DYNB-AIO Analog I\/O Base Board Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CP-DYNB-AIO\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP-DYNB-AIO\u003c\/strong\u003e Analog I\/O Base Board Module, operates as a dedicated hardware component for 16-channel analog input\/output processing within CP-DYN backplane platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP-DYNB-AIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CP-DYN backplane slot dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 analog input\/output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eUniversal analog (voltage \/ current configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCP-DYN backplane systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eBase board module for rack or chassis installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop \u0026amp; Channel-to-Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eDesigned to support multi-point field signal processing, the module incorporates board-level channel-to-channel isolation to prevent ground loop currents across mixed voltage and current field circuits. Integrated analog front-end filtering reduces high-frequency interference on 4-20 mA current loops, ensuring signal integrity across high-density I\/O distributions on the CP-DYN backplane bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are individual channels configured between 4-20 mA current and voltage modes?\u003c\/p\u003e\n\u003cp\u003eA: Channel modes are selected via DIP switches or DIP jumpers on the base board PCB in combination with system software parameter assignments.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be extracted or inserted while the CP-DYN rack backplane is energized?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping must conform to standard CP-DYN chassis maintenance procedures; field power to the analog loops should be isolated prior to removing the module from the rack slot.\u003c\/p\u003e\n\u003cp\u003eQ: What shielding method is recommended for the field wiring connected to the 16 analog channels?\u003c\/p\u003e\n\u003cp\u003eA: Use individual shielded twisted-pair cables for each analog loop, grounding all shields at a single point on the chassis earth ground bar to suppress EMI coupling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign the base board module with the designated rack or chassis slot guides on the CP-DYN backplane.\u003c\/li\u003e\n\u003cli\u003eSlide the module firmly into the slot until the edge connectors engage completely with the backplane bus.\u003c\/li\u003e\n\u003cli\u003eTighten top and bottom retaining screws to secure the module mechanically against vibration.\u003c\/li\u003e\n\u003cli\u003eRoute field analog signal lines through dedicated wire troughs, keeping them physically separated from high-voltage AC cables.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields to the dedicated system earth grounding point prior to powering on the I\/O loops.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53615940501813,"sku":"CP-DYNB-AIO","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CP-DYNB-2DI_8bf1ea9b-a9a2-4f71-8a77-a99498426f21.png?v=1789876925","url":"https:\/\/www.5gplc.com\/products\/honeywell-cp-dynb-aio-analog-i-o-base-board-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}