{"product_id":"honeywell-cc-ppix01-series-c-pulse-input-module","title":"Honeywell CC-PPIX01 Series C Pulse Input Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PPIX01 (PIM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Pulse Input Module designed for Series C Experion PKS systems. It provides precise pulse measurement and reliable signal processing for both single and dual-channel configurations. The module supports redundant operation through IOTA model\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TPIX11\u003c\/strong\u003e, making it suitable for critical control and monitoring applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PPIX01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePulse Input Module (PIM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOTA Model:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCC-TPIX11 (Redundant, 12\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 single or 4 dual (mixed configurations supported)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSingle Channel: 0–100 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual Pulse Channel: 0–10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.001% of reading (0.5 Hz–100 kHz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–35 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Trip Points:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh Setting: Low→High 8.4 V, High→Low 7.7 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow Setting: Low→High 2.8 V, High→Low 2.0 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Edge Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRising edge (default) or configurable to falling edge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation \u0026amp; Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-impedance inputs for safe field connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCounting and monitoring pulses from flow meters, rotary encoders, or energy meters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control systems in chemical, oil \u0026amp; gas, and utility industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant configurations for mission-critical systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this module handle both single and dual pulse inputs?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PPIX01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports 8 single inputs or 4 dual inputs, including mixed configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat is the maximum frequency supported?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-channel inputs support up to 100 kHz, while dual channels support up to 10 kHz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow configurable are the input edge settings?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module defaults to rising edge detection but can be configured for falling edge detection per channel.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52237130694965,"sku":"CC-PPIX01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CC-PAIN01_e53b5cff-ba03-413e-97ac-04991a27340e.jpg?v=1768816009","url":"https:\/\/www.5gplc.com\/products\/honeywell-cc-ppix01-series-c-pulse-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}