{"product_id":"honeywell-cc-pdob01-51405043-176-digital-output-24v-module","title":"Honeywell CC-PDOB01  51405043-176 Digital Output 24V Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PDOB01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51405043-176\u003c\/strong\u003e Digital Output 24V Module, operates as a dedicated hardware component for discrete high-density field load switching within Experion PKS C300 I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PDOB01 (Part Number: 51405043-176)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C300 I\/O Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC Backplane Bus Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eBussed Out Digital Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Loop Power Execution\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates robust channel-to-channel isolation and surge suppression to decouple field-side electrical noise from internal backplane logic. Output channels operate in a bussed configuration powered by a 24 VDC nominal field supply up to a 30 VDC maximum limit, delivering deterministic state execution for solenoids, relays, and indicator circuits. Channel-level diagnostic logic monitors output driver states to prevent unintended loop energization under fault conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-PDOB01 module support hot-swapping under live rack conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports Removal and Insertion Under Power (RIUP) when mounted on a standard Experion IOTA, allowing hot-swap operations without interrupting adjacent I\/O channel communication on the backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum field load voltage permitted across the output channels?\u003c\/p\u003e\n\u003cp\u003eA: The digital output channels are rated for a maximum load voltage of 30 VDC. Operating the channels above 30 VDC will risk triggering overvoltage protection or damaging onboard driver circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: How is field power routed to the 32 digital output channels?\u003c\/p\u003e\n\u003cp\u003eA: Field power is supplied via a bussed configuration through the corresponding Input Output Termination Assembly (IOTA), distributing 24 VDC power across all 32 switching channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the Input Output Termination Assembly (IOTA) position to ensure keyed slot pins align with the CC-PDOB01 module connector.\u003c\/li\u003e\n\u003cli\u003eSeat the module firmly onto the IOTA mounting base until the retention latches click into place.\u003c\/li\u003e\n\u003cli\u003eTorque all panel mounting screws to secure mechanical grounding paths between the IOTA shield bar and the enclosure frame ground.\u003c\/li\u003e\n\u003cli\u003eVerify that the external 24 VDC field supply loop voltage does not exceed 30 VDC before energizing field output circuits.\u003c\/li\u003e\n\u003cli\u003eEnsure field cable shields are grounded at a single point on the termination block ground bus to suppress electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53594656637237,"sku":"CC-PDOB01 51405043-176","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CC-PDOB0151405043-1761_Cocoai.png?v=1789527706","url":"https:\/\/www.5gplc.com\/products\/honeywell-cc-pdob01-51405043-176-digital-output-24v-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}