{"product_id":"honeywell-bc1000a0220u-e-control-module","title":"Honeywell BC1000A0220U\/E Control Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell BC1000A0220U\/E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBC1000A\u003c\/strong\u003e Control Module, operates as a dedicated hardware component for optical flame detection and burner safety switching within industrial combustion systems. Operating on 220 to 230 VAC line power, it processes raw flame signals from UV sensors or flame rods to actuate internal safety control relays.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBC1000A0220U\/E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eKorea\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN Panel Mounting Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8 W Max at 220 to 230 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e220 to 230 VAC (+10% \/ -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame Response Time\u003c\/td\u003e\n\u003ctd\u003e2 sec (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd\u003eC7027A, C7035A UV Sensors \/ Flame Rods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; DCS Integration\u003c\/h3\u003e\n\u003cp\u003eThe BC1000A0220U\/E integrates channel-to-channel isolation parameters that separate line-voltage relay contact circuits from sensitive low-voltage flame sensing inputs. This internal electrical barrier blocks common-mode voltage spikes and electrical noise propagation across burner control networks. The isolation structure ensures stable flame presence monitoring and prevents cross-talk interference when operating in close proximity to 4-20 mA HART loop protocol field transmitters and central DCS monitoring units.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power input is required to operate the BC1000A0220U\/E control module?\u003c\/p\u003e\n\u003cp\u003eA: The module operates directly on a 220 to 230 VAC supply at 50\/60 Hz with a nominal power consumption of 8 W.\u003c\/p\u003e\n\u003cp\u003eQ: Which flame sensors are compatible with the BC1000A0220U\/E inputs?\u003c\/p\u003e\n\u003cp\u003eA: It interfaces directly with Honeywell C7027A and C7035A series ultraviolet sensors, as well as standard industrial flame rectification rods.\u003c\/p\u003e\n\u003cp\u003eQ: What is the typical flame failure response time for this safety switch module?\u003c\/p\u003e\n\u003cp\u003eA: The internal relay executes a fail-safe contact trip within a nominal 2 seconds of flame signal loss.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize all main AC power circuits prior to installing or servicing the BC1000A0220U\/E module base.\u003c\/li\u003e\n\u003cli\u003eSecurely mount the module base onto the enclosure DIN-rail or panel backplate using standard mounting hardware.\u003c\/li\u003e\n\u003cli\u003eRoute flame sensor cabling in a separate dedicated grounded conduit away from high-voltage ignition leads to eliminate stray signal induction.\u003c\/li\u003e\n\u003cli\u003eVerify correct terminal polarity for the 220-230 VAC mains input and signal connections before applying power to the system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53599346950453,"sku":"BC1000A0220U\/E","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BC1000A0220UE.png?v=1789614785","url":"https:\/\/www.5gplc.com\/products\/honeywell-bc1000a0220u-e-control-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}