{"product_id":"honeywell-900tbr-0001-high-voltage-terminal-strip","title":"Honeywell 900TBR-0001 High Voltage Terminal Strip","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900TBR-0001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900TBR-0001\u003c\/strong\u003e High Voltage Terminal Strip, operates as a dedicated hardware component for high-voltage physical signal termination and wiring isolation within Honeywell ControlEdge HC900 rack assemblies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900TBR-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.09 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard HC900 I\/O module width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C (-4 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive physical connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eBarrier-style terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition Count\u003c\/td\u003e\n\u003ctd\u003e20 position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eHigh voltage rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Galvanic De-coupling\u003c\/h3\u003e\n\u003cp\u003eThe 900TBR-0001 terminal assembly establishes dedicated wiring connections for high-voltage I\/O signals entering the HC900 control rack. The barrier-style 20-position physical spacing maintains channel-to-channel isolation parameters required to prevent arc-over and signal crosstalk across adjacent field circuits. Designed to interface with process control modules, the physical construction supports 4-20 mA HART loop protocol routing and high-voltage AC\/DC discrete signals while maintaining galvanic isolation barriers between field-side field wiring and internal backplane logic structures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What screw torque specification should be applied to the 20 terminal positions on the 900TBR-0001?\u003c\/p\u003e\n\u003cp\u003eA: Field wiring screws should be torqued to a standard 0.5 to 0.6 Nm (4.4 to 5.3 in-lbs) to ensure gas-tight mechanical retention without damaging the internal barrier lug threads.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 900TBR-0001 barrier strip be removed from an I\/O module while field power is applied?\u003c\/p\u003e\n\u003cp\u003eA: Removal under energized conditions is not recommended for high-voltage circuits. Terminal connections must be isolated and de-energized prior to detaching the terminal strip to prevent electrical shock or arc flash events.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that all field-side power sources connected to the 20-position terminal strip are completely de-energized and locked out before wiring installation.\u003c\/li\u003e\n\u003cli\u003eStrip field conductor insulation to a uniform length of 6 mm to ensure full insertion into the barrier-style terminal clamps without exposing bare wire.\u003c\/li\u003e\n\u003cli\u003eRoute incoming field signal conductors through dedicated wire raceways, keeping high-voltage power lines physically segregated from low-level analog or communication cabling by at least 200 mm.\u003c\/li\u003e\n\u003cli\u003eSecure the terminal strip assembly to the front of the corresponding HC900 I\/O module until the mechanical locking tabs are fully seated.\u003c\/li\u003e\n\u003cli\u003eConnect all cable shields to the system signal ground bar using a single-point grounding layout to eliminate ground loops across field loops.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53520091480373,"sku":"900TBR-0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/900TBR-0001_Cocoai.png?v=1788934642","url":"https:\/\/www.5gplc.com\/products\/honeywell-900tbr-0001-high-voltage-terminal-strip","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}