{"product_id":"honeywell-900p24-0301-power-supply-module-controledge-hc900","title":"Honeywell 900P24-0301 Power Supply Module | ControlEdge HC900","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900P24-0301\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900P24\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for direct voltage regulation within ControlEdge HC900 process and safety control system architectures. The unit accepts an input voltage range of 21 to 29 VDC at a 72.5 W rating, converting field DC power to a regulated 24 VDC, 60 W output bus. This assembly provides direct physical and electrical execution for continuous power distribution across controllers, I\/O modules, and remote racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900P24-0301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137 mm x 72.6 mm x 42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e72.5 W input rating (60 W regulated output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51450997-005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e21 to 29 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A for 3 ms at 29 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-up Time\u003c\/td\u003e\n\u003ctd\u003e20 ms at 115 VAC, 60 Hz (maximum load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eScrew-type terminals, supports #12-22 AWG wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; DCS Power Infrastructure\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900P24-0301\u003c\/strong\u003e power module utilizes internal galvanic separation channels between the primary input terminals and the internal backplane output lines to isolate sensitive processing logic from field DC bus fluctuations. Integrated channel-to-channel isolation prevents ground loop currents from circulating between distributed I\/O racks and field-side instruments, supporting stable signal acquisition across 4-20 mA HART loop protocol field networks. The power supply maintains regulated DC bus levels during short-term input voltage drops up to its 20 ms hold-up threshold.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What protective measures are integrated into the 900P24-0301 against input current spikes?\u003c\/p\u003e\n\u003cp\u003eA: The module contains an internal, non-replaceable fuse rated to limit fault currents, along with circuit conditioning to absorb an inrush current spike up to 30 A for 3 ms at 29 VDC input.\u003c\/p\u003e\n\u003cp\u003eQ: What conductor sizes are supported by the input and output wiring terminals of the 900P24-0301?\u003c\/p\u003e\n\u003cp\u003eA: The integrated screw-type terminal blocks accept field wiring gauges ranging from #12 to #22 AWG.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect a dedicated chassis grounding conductor from the module ground lug directly to the cabinet protective earth (PE) busbar prior to applying input power.\u003c\/li\u003e\n\u003cli\u003eEnsure all field power wiring terminated at the screw terminals (#12 to #22 AWG) is torqued securely to prevent high-resistance thermal junctions.\u003c\/li\u003e\n\u003cli\u003eMaintain clear vertical airflow spacing around the module chassis to allow natural thermal heat dissipation during continuous 60 W load operation.\u003c\/li\u003e\n\u003cli\u003eConfirm that external DC supply feeds stay strictly within the 21 to 29 VDC operating window before energizing the system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53531600093493,"sku":"900P24-0301","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/900P24-0301_Cocoai.png?v=1789095425","url":"https:\/\/www.5gplc.com\/products\/honeywell-900p24-0301-power-supply-module-controledge-hc900","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}