{"product_id":"honeywell-900b16-0101-controledge-hc900-analog-output-module","title":"Honeywell 900B16-0101 ControlEdge HC900 Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900B16-0101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900B16\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for 16-channel current loop control execution within ControlEdge HC900 automation architectures. The unit drives analog control signals up to 21 mA into maximum resistive loads of 750 ohms per channel. Operating across 16 independent outputs, the module converts digital control block commands from the central processor into continuous physical current signals for field actuators and positioners.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900B16-0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.27 kg (0.60 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22 mm W x 124 mm D x 126 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane power load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0 to 21 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd\u003e750 ohms max per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; 4-20 mA HART Loop Protocol Performance\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900B16-0101\u003c\/strong\u003e module features channel-to-channel isolation and individual loop current regulation to protect analog control signals from ground potential differences. Built-in digital-to-analog processing drives precise current signals across all 16 channels while preventing cross-talk interference. The internal backplane interface maintains signal isolation between internal CPU bus logic and field-side wiring loops, supporting stable signal transmission for field devices configured for 4-20 mA HART loop protocol communications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum resistive load supported per channel on the 900B16-0101 module?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 16 analog output channels can drive up to 21 mA into a maximum loop resistance of 750 ohms.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 900B16-0101 analog output module be inserted into an active HC900 rack under power?\u003c\/p\u003e\n\u003cp\u003eA: Removal and Insertion Under Power (RIUP) is supported when using compatible ControlEdge HC900 rack assemblies, provided all field terminal block disconnect procedures and plant safety protocols are followed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the module terminal block is wired using shielded twisted-pair cables with shields grounded at a single point to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify that loop load impedance on each active output channel does not exceed the maximum rating of 750 ohms.\u003c\/li\u003e\n\u003cli\u003eSecure the 900B16-0101 firmly into the rack slot using the top and bottom retention latches to maintain proper backplane pin alignment.\u003c\/li\u003e\n\u003cli\u003eMaintain clear vertical airflow paths above and below the module rack to operate within the 0 to 60 deg C ambient temperature specification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53531620901173,"sku":"900B16-0101","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/900B16-0101.png?v=1789096192","url":"https:\/\/www.5gplc.com\/products\/honeywell-900b16-0101-controledge-hc900-analog-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}