{"product_id":"honeywell-900b16-0001-16-channel-analog-output-module","title":"Honeywell 900B16-0001 16-Channel Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900B16-0001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900B16-0001\u003c\/strong\u003e 16-Channel Analog Output Module, operates as a dedicated hardware component for converting digital logic commands into current output signals within Honeywell HC900 Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900B16-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard HC900 single-slot I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane: 5 VDC at 350 mA max, 24 VDC at 700 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels (grouped into 4 isolated sets of 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e0 to 21.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd\u003eUp to 750 Ohms per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd\u003e13+ bits (1 part in 13,332)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% full scale under reference conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 36 VDC at 700 mA per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Type\u003c\/td\u003e\n\u003ctd\u003e900TCK-0001 (36-position Euro-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Analog Loop Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe 900B16-0001 analog output module drives up to 16 current loops across 4 isolated group channels (channels 1-4, 5-8, 9-12, and 13-16). Featuring 500 VDC galvanic isolation between channel groups and internal backplane logic, the card shields control processing units from field earth potentials and common-mode noise. Supporting 4-20 mA HART loop protocol field devices, the module incorporates continuous self-diagnostics that audit factory and field calibration parameters while verifying output current flow feedback on every channel execution cycle.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many 900B16-0001 modules can be installed in a single HC900 rack when using internal backplane power?\u003c\/p\u003e\n\u003cp\u003eA: A maximum of 2 modules per rack can be powered via the internal 24 VDC backplane; additional modules require external 18 to 36 VDC power supplies.\u003c\/p\u003e\n\u003cp\u003eQ: What level of galvanic isolation does the module provide between output channel groups?\u003c\/p\u003e\n\u003cp\u003eA: The module provides 500 VDC galvanic isolation between the four channel groups as well as between field output circuits and system logic.\u003c\/p\u003e\n\u003cp\u003eQ: Which terminal block assembly is required to connect field wiring to the 900B16-0001 card?\u003c\/p\u003e\n\u003cp\u003eA: The module connects to field wiring using the 36-position Euro-style 900TCK-0001 terminal block assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the rack or verify system slot redundancy conditions before inserting the 900B16-0001 module into its subrack position.\u003c\/li\u003e\n\u003cli\u003eAlign the module card edges with the slot guides and push firmly until the backplane connector latches smoothly into place.\u003c\/li\u003e\n\u003cli\u003eWire field actuators and 4-20 mA devices to the 900TCK-0001 Euro-style terminal block using recommended wire gauges.\u003c\/li\u003e\n\u003cli\u003eSegregate analog output signal cabling from high-voltage AC distribution power lines inside the cabinet wire trunks.\u003c\/li\u003e\n\u003cli\u003eConnect cable shield drain wires directly to the cabinet ground bar to ensure optimal signal integrity and EMI immunity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53516726206773,"sku":"900B16-0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/900B16-0001_Cocoai.png?v=1788923382","url":"https:\/\/www.5gplc.com\/products\/honeywell-900b16-0001-16-channel-analog-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}