{"product_id":"honeywell-900a16-0101-900tck-0101-high-level-analog-module","title":"Honeywell 900A16-0101 + 900TCK-0101 High-Level Analog Module","description":"\u003cp\u003eConfigured for high-level analog and temperature signal acquisition within ControlEdge HC900 platforms, the \u003cstrong\u003eHoneywell 900A16-0101 + 900TCK-0101\u003c\/strong\u003e (\u003cstrong\u003e900A16-0101 + 900TCK-0101\u003c\/strong\u003e High-Level Analog Module) provides direct physical\/electrical execution. It captures precise field transmitter, voltage, current, thermocouple, and RTD data while maintaining robust point-to-point and channel-to-system galvanic isolation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e900A16-0101\u003c\/strong\u003e: 16-channel high-level analog input module engineered for voltage and current signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e900TCK-0101\u003c\/strong\u003e: 8-channel universal analog input module dedicated to thermocouple, RTD, resistance, and millivolt measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900A16-0101 + 900TCK-0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900 Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Backplane Draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels (900A16) \/ 8 Channels (900TCK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interface\u003c\/td\u003e\n\u003ctd\u003e4-20 mA HART Loop Protocol Compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe architecture of the \u003cstrong\u003eHoneywell 900A16-0101 + 900TCK-0101\u003c\/strong\u003e incorporates rigid channel-to-channel isolation and supports 4-20 mA HART loop protocol integration pathways across field transmitters. By enforcing 400 VDC point-to-point isolation and 1 kVDC isolation to logic on the high-level input module, alongside channel-to-system galvanic isolation on the temperature module, the assembly prevents common-mode noise and ground loops. Furthermore, integrated cold junction compensation (CJC) on thermocouple inputs and high common-mode noise rejection (\u0026gt;90 dB at 120 VAC) ensure precision signal conversion in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input types are supported by the Honeywell 900A16-0101 module?\u003c\/p\u003e\n\u003cp\u003eA: It supports high-level voltage and current (V, mA) signals across 16 isolated analog input channels with an input impedance greater than 1 megohm for voltage and 250 ohms for current.\u003c\/p\u003e\n\u003cp\u003eQ: Can the Honeywell 900TCK-0101 module process multiple thermocouple types?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it supports universal thermocouple types J, K, T, E, N, R, S, B, as well as standard RTDs, resistance, and millivolt signals.\u003c\/p\u003e\n\u003cp\u003eQ: Are these input modules hot-swappable during active controller operation?\u003c\/p\u003e\n\u003cp\u003eA: Hot-plugging I\/O modules depends on rack power configuration and system backplane specifications. Power isolation protocols should be observed to prevent transient bus errors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Slide and secure each module firmly into its designated slot on the ControlEdge HC900 backplane chassis to ensure positive connector engagement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route low-level analog and thermocouple extension wire physically apart from high-voltage AC power lines and variable frequency drive cables to eliminate induced noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Terminate signal cable shields to the designated cabinet grounding bar to maintain electromagnetic compatibility and noise rejection performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torquing:\u003c\/strong\u003e Tighten all removable terminal block screws to manufacturer specifications to prevent high-resistance contact and measurement drift.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67682101625141,"sku":"900A16-0101 + 900TCK-0101","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/900H02-0202__1_7a9e0458-6779-491e-86d8-8417b29d0ec2.png?v=1791871075","url":"https:\/\/www.5gplc.com\/products\/honeywell-900a16-0101-900tck-0101-high-level-analog-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}