{"product_id":"honeywell-900a16-0001-hc900-series-analog-input-module","title":"Honeywell 900A16-0001 HC900 Series Analog Input Module","description":"\u003cp\u003eConfigured for 16-channel isolated signal acquisition in Honeywell Experion PKS and HC900 platforms, the \u003cstrong\u003eHoneywell 900A16-0001\u003c\/strong\u003e (\u003cstrong\u003e900A16\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900A16-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.397 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137 mm x 35.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC standard, configurable ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e250 ohms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1 percent of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Rate\u003c\/td\u003e\n\u003ctd\u003eConfigurable, typically 10 ms\/channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 percent to 95 percent RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eSignal quality validation, open-circuit detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 900A16-0001 module incorporates galavanic channel-to-channel and channel-to-bus isolation across all 16 analog inputs, preventing ground loops and common-mode potential differences from distorting process variable readings. Designed to interface directly with field instruments, the 250 ohm input resistance allows direct processing of 4-20 mA HART loop current signals. Integrated 16-bit analog-to-digital conversion combines with continuous channel diagnostics, providing real-time open-circuit detection and signal quality monitoring for critical process control loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does channel-to-channel isolation benefit field instrumentation signals on the 900A16-0001?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic separation between individual channels prevents potential differences between grounded field transmitters from introducing measurement offsets or causing cross-channel interference.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic flags are generated by the module during sensor fault conditions?\u003c\/p\u003e\n\u003cp\u003eA: The module executes real-time open-circuit detection and signal quality checks, asserting diagnostic alarms to the central controller when current loop values fall below standard operating thresholds.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate loop power supplies before wiring field transmitters to the module terminal blocks to avoid overcurrent damage.\u003c\/li\u003e\n\u003cli\u003eMaintain individual twisted shielded pairs for each 4-20 mA loop, grounding the cable shield at a single point on the chassis earth terminal.\u003c\/li\u003e\n\u003cli\u003eVerify that terminal block screws are tightened to standard torque specifications to maintain solid low-resistance physical contacts.\u003c\/li\u003e\n\u003cli\u003eEnsure enclosure ambient conditions remain within -20 deg C to +60 deg C with non-condensing relative humidity below 95 percent.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53525532082485,"sku":"900A16-0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/900A16-0001_Cocoai.png?v=1789003559","url":"https:\/\/www.5gplc.com\/products\/honeywell-900a16-0001-hc900-series-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}