{"product_id":"honeywell-8u-pwsp01-cn-series-8-power-supply-module","title":"Honeywell 8U-PWSP01-CN Series 8 Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 8U-PWSP01-CN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8U-PWSP01-CN\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for regulated system bus voltage delivery within Honeywell Experion PKS Series 8 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8U-PWSP01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7 cm x 14 cm x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC \/ VDC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2000 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Monitoring\u003c\/td\u003e\n\u003ctd\u003eSix internal temperature sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation \u0026amp; Voltage Regulation Profiles\u003c\/h3\u003e\n\u003cp\u003eThe module converts wide-range AC or DC input power into a tightly regulated 24 VDC power rail delivering up to 20 A to backplane I\/O channels. Internal galvanic isolation rated at 2000 VAC prevents line transients and noise from coupling onto the internal DC distribution bus. Integrated circuitry maintains output regulation within +\/-0.5% across dynamic load steps. Six internal thermal sensors continuously monitor operating states, providing contact signaling and status indication to protect against over-temperature events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 8U-PWSP01-CN support redundant power configurations on the Series 8 rack carrier?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports redundant parallel operation to allow uninterrupted 24 VDC system power delivery during a single supply failure.\u003c\/p\u003e\n\u003cp\u003eQ: What input power sources are compatible with the primary terminals?\u003c\/p\u003e\n\u003cp\u003eA: The internal switching power circuit accepts an input range of 100-240 VAC or VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation level exists between input power and system ground?\u003c\/p\u003e\n\u003cp\u003eA: The hardware architecture provides 2000 VAC galvanic isolation between input power terminals and the internal control logic circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the AC\/DC main line circuit breaker is de-energized prior to seating or unseating the 8U-PWSP01-CN power module in the Series 8 rack slot.\u003c\/li\u003e\n\u003cli\u003eVerify that input line, neutral\/DC potential, and protective earth (PE) wires are fully secured to terminal connections before applying power.\u003c\/li\u003e\n\u003cli\u003eEstablish a direct low-impedance ground connection from the rack chassis grounding stud to the main enclosure ground bar.\u003c\/li\u003e\n\u003cli\u003eMaintain proper vertical clearance above and below the module chassis to allow natural air circulation across the heat sink surfaces.\u003c\/li\u003e\n\u003cli\u003eConfirm that total continuous 24 VDC load currents do not exceed the 20 A maximum rating under peak ambient operating conditions up to +70 deg C.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53449527886133,"sku":"8U-PWSP01-CN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/8C-PAIMA151454473-175_7d94ca8d-4749-4ade-8e59-df4faf2c353c.png?v=1788402037","url":"https:\/\/www.5gplc.com\/products\/honeywell-8u-pwsp01-cn-series-8-power-supply-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}