{"product_id":"honeywell-6561430051-plc-cable","title":"Honeywell 6561430051 PLC Cable","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 6561430051\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e6561430051\u003c\/strong\u003e PLC Cable, operates as a dedicated hardware component for analog and digital signal transmission between C300 controllers and Field Termination Assemblies (FTAs) within Honeywell Experion PKS and TDC 3000 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6561430051\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard cabinet interface length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive signal conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePLC Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS, TDC 3000, C300 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Compatibility\u003c\/td\u003e\n\u003ctd\u003eAnalog and digital I\/O signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterconnect Target\u003c\/td\u003e\n\u003ctd\u003eController to Field Termination Assembly (FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 6561430051 cable maintains low channel-to-channel crosstalk when routing mixed analog and discrete I\/O lines between C300 controllers and FTAs. It preserves required line impedances for 4-20 mA HART loop protocol signaling, ensuring digital diagnostic data superimposed on analog process variables passes without distortion. Dedicated internal conductor shielding and low-resistance grounding drain wires prevent common-mode noise interference across adjacent field channels, protecting critical loops against environmental electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 6561430051 cable be connected or disconnected while the C300 controller rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: Unplugging live signal cables between a controller and an FTA can interrupt active control loops and cause fault trips. It is recommended to bypass affected I\/O channels in system software prior to disconnecting physical wiring.\u003c\/p\u003e\n\u003cp\u003eQ: How should cable shield terminations be handled during system wiring?\u003c\/p\u003e\n\u003cp\u003eA: Shield drain wires must be connected to designated chassis grounding points on the FTA or enclosure frame at a single end to eliminate ground loop currents and maintain shield effectiveness.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that C300 controller power and field loop power are isolated or safely bypassed prior to cable connection.\u003c\/li\u003e\n\u003cli\u003eRoute the cable through designated cabinet wiring channels, ensuring minimum bend radius specs are maintained to avoid internal conductor fatigue.\u003c\/li\u003e\n\u003cli\u003eAlign connector pins with the matching receptacle on the C300 node or FTA interface board before applying firm, straight seating pressure.\u003c\/li\u003e\n\u003cli\u003eTighten connector thumbscrews or latching hardware to secure the assembly against vibration and maintain electrical contact stability.\u003c\/li\u003e\n\u003cli\u003eEnsure shield drain wires are clamped to a single grounding bus to prevent electromagnetic interference from affecting analog loop signals.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53188031152437,"sku":"6561430051","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51308051-200_6b58f33e-f566-41d5-b52f-4c732c10afe6.png?v=1784532088","url":"https:\/\/www.5gplc.com\/products\/honeywell-6561430051-plc-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}