{"product_id":"honeywell-51404172-175-power-system-backpanel","title":"Honeywell 51404172-175 Power System Backpanel","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51404172-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51404172\u003c\/strong\u003e Back Panel Board, operates as a dedicated hardware component for power distribution routing and redundant supply management within Honeywell 5140 Series Power System cages.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51404172-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10.00 lbs (4.54 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive distribution backpanel with integrated charger circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell 5140 Series Power System \/ Universal Control Network (UCN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Support\u003c\/td\u003e\n\u003ctd\u003eRedundant UCN power supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Component\u003c\/td\u003e\n\u003ctd\u003eUniversal XPM Charger Board (51309206-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated toggle switch for manual system control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eConformal coating for harsh environmental protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eRack-mounted within system cage assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe backpanel board establishes physical bus traces and power rail distribution to manage dual redundant UCN power supply inputs. Built-in channel-to-channel isolation on individual supply branches suppresses high-frequency switching noise and common-mode transients, preventing power line disturbances from coupling into adjacent 4-20 mA HART loop protocol instruments or digital system communication nodes. Conformal coating applied across all trace paths protects high-density copper tracks from atmospheric contaminants and moisture condensation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 51404172-175 board support redundant power configurations?\u003c\/p\u003e\n\u003cp\u003eA: The board provides isolated power bus channels and physical slot connectors designed to accept dual redundant UCN power supply modules for automatic load sharing and failover.\u003c\/p\u003e\n\u003cp\u003eQ: What function does the integrated Universal XPM Charger Board perform on this assembly?\u003c\/p\u003e\n\u003cp\u003eA: The onboard Universal XPM Charger Board (51309206-175) regulates charging voltage and current paths for system battery backup modules attached to the power chassis.\u003c\/p\u003e\n\u003cp\u003eQ: Can the backpanel assembly be installed in standard industrial racks?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the board is engineered for direct rack-mounting inside standard Honeywell 5140 Series Power System cages.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all primary AC and secondary battery power feeds to the power system cage before installing or replacing the backpanel assembly.\u003c\/li\u003e\n\u003cli\u003eMount the board securely within the system cage chassis using all designated mounting screws to establish a firm mechanical chassis ground.\u003c\/li\u003e\n\u003cli\u003eVerify that terminal header connections and supply cable connectors are fully latched before re-energizing redundant power supply units.\u003c\/li\u003e\n\u003cli\u003eInspect the conformally coated surfaces for physical damage prior to installation, taking standard ESD precautions during handling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53631757615413,"sku":"51404172-175","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51404172-175_Cocoai.png?v=1790145255","url":"https:\/\/www.5gplc.com\/products\/honeywell-51404172-175-power-system-backpanel","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}