{"product_id":"honeywell-51402614-100-ethernet-board-module","title":"Honeywell 51402614-100 Ethernet Board Module","description":"\u003cp\u003eConfigured for TCP\/IP-based communication in Honeywell TPS\/LCN operator and controller stations, the \u003cstrong\u003eHoneywell 51402614-100\u003c\/strong\u003e (\u003cstrong\u003e51402614-100\u003c\/strong\u003e Ethernet Board Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51402614-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 80 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC +\/- 5% (Max 3 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Board Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, ARP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TPS\/LCN operator and controller stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eBoard-level installation within station hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation \u0026amp; Network Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eDesigned for real-time process control data routing, the module executes deterministic Ethernet frame transfers across station backplane architectures. Integrated channel-to-channel isolation safeguards sensitive internal logic circuitry from transient voltage spikes and differential ground potential offsets. The onboard physical layer interface manages ARP packet verification and TCP\/IP stack execution, maintaining continuous connection integrity between operator stations and low-level process controllers without imposing CPU processing overhead on the host node.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input supply voltage does the 51402614-100 board require from the host backplane?\u003c\/p\u003e\n\u003cp\u003eA: The board operates on a regulated 5 VDC +\/- 5% power rail, consuming a maximum power load of 3 W during active network data transmission.\u003c\/p\u003e\n\u003cp\u003eQ: Which network communication protocols are implemented on this hardware module?\u003c\/p\u003e\n\u003cp\u003eA: The module directly supports TCP\/IP and ARP protocols over Ethernet interfaces operating at data rates up to 10 Mbps.\u003c\/p\u003e\n\u003cp\u003eQ: How is physical frame grounding established during board installation?\u003c\/p\u003e\n\u003cp\u003eA: Grounding is established via the board mounting chassis points and frame retention screws, which bond the ground plane directly to the host enclosure chassis upon installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all electrical power sources from the target Honeywell TPS\/LCN station chassis before accessing internal slots.\u003c\/li\u003e\n\u003cli\u003eWear a grounded wrist strap attached to frame ground to prevent electrostatic discharge damage to board components.\u003c\/li\u003e\n\u003cli\u003eAlign the 51402614-100 circuit board edges with the card guide rails inside the designated station slot.\u003c\/li\u003e\n\u003cli\u003ePress the module smoothly into place until the multi-pin edge connectors seat completely into the host backplane.\u003c\/li\u003e\n\u003cli\u003eTighten all mechanical mounting screws to ensure proper electrical contact for frame grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003eVerify external coaxial or twisted-pair network cable connections before re-energizing the station power supply.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53594652737845,"sku":"51402614-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51402614-100_Cocoai.png?v=1789527350","url":"https:\/\/www.5gplc.com\/products\/honeywell-51402614-100-ethernet-board-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}