{"product_id":"honeywell-51401288-100-experion-series-intrinsically-safe-temperature-transmitter-module","title":"Honeywell 51401288-100 Experion Series Intrinsically Safe Temperature Transmitter Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 51401288-100 functions as a high-precision, intrinsically safe temperature transmitter board designed for Honeywell Distributed Control System (DCS) architectures. This hardware card interfaces directly with raw thermal sensors located in hazardous process zones, providing localized digitization, signal linearization, and protocol encoding. We supply this mission-critical field network module exclusively in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed condition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto eliminate measurement drift, protect explosive field environments from electrical energy faults, and ensure precise thermal profile tracking.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51401288-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eData Control System \/ DCS Module Board Rack Component\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Configurations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD (Pt100, Pt1000) \/ Thermocouple (Types J, K, E, T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Interfacing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20mA HART 7 (2-wire loop) \/ 0-10V DC (3-wire topology)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Measurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-200°C to +850°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntrinsic Safety Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e[Ex ia] IIC T6 Ga \/ Class I, II, III Division 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Temperature Limit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Protection Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP66 certified \/ NEMA 4X compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.20 lbs (1.45 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolates Fault Energy in Hazardous Zones:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in energy-limiting Zener barriers and galvanic isolation circuits restrict current and voltage levels flowing to the field side. This architecture secures full [Ex ia] IIC T6 Ga and Class I, II, III Div 1 ratings, preventing explosive gas or dust ignition without requiring heavy explosion-proof piping layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDecodes Real-Time Asset Analytics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module runs the advanced HART 7 communication protocol over standard 2-wire 4-20mA current loops. This allows the host controller to read secondary device temperatures, sensor wire failure faults, and calibration timestamp matrices simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstands Heavy Washdowns and Corrosive Air:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe robust IP66 (NEMA 4X) rated housing configuration seals the internal processing circuitry completely against high-pressure water jets, fine salt spray, and abrasive coal dust layers common in seaside refineries and processing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Sensor Signal Conversion Drift:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-sensor input front-end measures a massive thermal sweep from -200°C up to +850°C. High-bit digitization circuitry stabilizes raw microvolt and ohm inputs, filtering out high-frequency electromagnetic interference (EMI) radiating from close-proximity heating elements or heavy induction motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this single 51401288-100 hardware module accept both RTD and Thermocouple wires simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal processing firmware accommodates multiple sensor curves, including Pt100, Pt1000, and standard J, K, E, and T type thermocouples. You must map individual channel input settings via your Experion system software or a field communicator tool to match your specific field sensor installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this temperature module a refurbished surplus card or an actual factory-fresh unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this product is 100% brand new, factory-original, and completely unused stock. It arrives in its native manufacturer anti-static protective wrapping with all original tracking barcodes, quality seals, and factory serialization labels fully intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation guidelines protect the module's intrinsic safety integrity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField technicians must strictly separate intrinsically safe field wiring paths from non-intrinsically safe power and backplane lines inside the cabinet. Run all sensor lines through dedicated blue conduit tracks, ground the internal chassis shield screw directly to your plant's instrument earth bus, and isolate power before mounting the 3.20 lbs card into the chassis slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52895897846069,"sku":"51401288-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51401288-100.png?v=1779093964","url":"https:\/\/www.5gplc.com\/products\/honeywell-51401288-100-experion-series-intrinsically-safe-temperature-transmitter-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}