{"product_id":"honeywell-51309218-125-mu-tamr03-low-level-analog-input-multiplexer-rtd-fta","title":"Honeywell 51309218-125 | MU-TAMR03 | Low Level Analog Input Multiplexer RTD FTA","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAMR03 (51309218-125)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Low Level Analog Input Multiplexer (LLMux) Field Termination Assembly designed specifically for Resistance Temperature Detector (RTD) inputs. This module serves as the critical physical interface between field-mounted temperature sensors and the Honeywell TDC 3000 or Experion PKS control systems.\u003c\/p\u003e\n\u003cp\u003eEngineered for high-density temperature monitoring, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAMR03 (51309218-125)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports 16 independent input channels. This specific hardware revision features rugged compression-style terminals, ensuring secure and vibration-resistant physical wire terminations for sensitive low-level signals. Note that this version is non-conformally coated and is intended for use in environments where CE compliance is not a regulatory requirement.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDetailed Engineering Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e: 16-Channel RTD Multiplexer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Level\u003c\/strong\u003e: Low Level Analog (optimized for ohms\/temperature conversion)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e: Compression terminals (screw-down)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Architecture\u003c\/strong\u003e: Single IOP (Input Output Processor) interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Redundancy\u003c\/strong\u003e: Non-redundant configuration only\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e: Non-conformally coated (standard board)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegulatory Status\u003c\/strong\u003e: Non-CE compliant version\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e: Approximately 5.0 kg (11.0 lbs) shipping mass\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Integration\u003c\/strong\u003e: Designed for standard Honeywell FTA mounting channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAMR03 (51309218-125)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically utilized in large-scale industrial plants where high-density RTD monitoring is required, such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBearing temperature monitoring for large rotating equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-point distillation column temperature profiling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeat exchanger efficiency monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral balance-of-plant temperature data acquisition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the MU-TAMR03 compatible with redundant IOPs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAMR03 (51309218-125)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a single IOP interface assembly and does not support redundant hardware architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module include protection for corrosive environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific part number (51309218-125) is not conformally coated. For applications in \"G3\" or corrosive environments, a coated version should be specified.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52467083804981,"sku":"MU-TAMR03 501309218-125","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/MU-TAMR03501309218-125.jpg?v=1774238171","url":"https:\/\/www.5gplc.com\/products\/honeywell-51309218-125-mu-tamr03-low-level-analog-input-multiplexer-rtd-fta","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}