{"product_id":"honeywell-51308373-175-rev-b2-cc-td0b11-digital-output-24v-iota-module","title":"Honeywell 51308373-175 Rev. B2 CC-TD0B11 Digital Output 24V IOTA Module","description":"\u003cp\u003eConfigured for discrete field device actuation in Honeywell Experion PKS platforms, the \u003cstrong\u003eHoneywell 51308373-175 Rev. B2\u003c\/strong\u003e (\u003cstrong\u003eCC-TD0B11\u003c\/strong\u003e Digital Output 24V IOTA Module) provides direct physical\/electrical execution. It operates as the hardware interface assembly to route control signals from processing electronics to 24 VDC external loads. The termination assembly provides dedicated screw terminal blocks and backplane connectors to establish secure electrical connectivity for field channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TD0B11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51308373-175 Rev. B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output I\/O Termination Assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003eOptocoupler isolated per channel group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail Mount \/ Chassis Integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 x 120 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W (Max backplane logic power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe module features channel-to-channel isolation and integrated surge absorption networks to safeguard internal DCS logic from field-side inductive kicks and voltage spikes. Designed for seamless interoperation with 4-20 mA HART loop protocol environments and high-density digital field control racks, the terminal assembly ensures low-impedance current paths. This signal conditioning profile minimizes cross-talk suppression failures and maintains fast digital switching response times across all output channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the revision B2 designation impact field replacement compatibility?\u003c\/p\u003e\n\u003cp\u003eA: Revision B2 maintains full backward functional compatibility with earlier revision hardware in the same series, allowing direct slot-for-slot replacement without requiring firmware reconfiguration in the Experion PKS software suite.\u003c\/p\u003e\n\u003cp\u003eQ: Are field output channels individually fused on the IOTA board?\u003c\/p\u003e\n\u003cp\u003eA: The CC-TD0B11 IOTA utilizes current-limiting electronic protection circuit paths along with centralized power distribution fuses to protect backplane traces against sustained field short circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting\u003c\/strong\u003e: Snap the IOTA base securely onto the standard DIN rail within the enclosure, ensuring the grounding clips make firm mechanical contact with the metal rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring \u0026amp; Terminations\u003c\/strong\u003e: Strip field wires to specified lengths and secure them into the screw terminals. Torque all terminal screws to 0.5 Nm to prevent high-resistance connections or wire pull-outs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Connect field cable shields directly to the cabinet signal ground bar at a single point to prevent ground loops and shield high-frequency noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Connection\u003c\/strong\u003e: Engage the ribbon cable from the corresponding C300 I\/O module into the IOTA header until the locking levers snap completely into place.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53472395755829,"sku":"CC-TD0B11","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CC-TD0B11_Cocoai.png?v=1788747925","url":"https:\/\/www.5gplc.com\/products\/honeywell-51308373-175-rev-b2-cc-td0b11-digital-output-24v-iota-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}