{"product_id":"honeywell-51306356-100-rev-a-cable-assemblies","title":"Honeywell 51306356-100 Rev.A Cable Assemblies","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51306356-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51306356-100\u003c\/strong\u003e Cable Assemblies, operates as a dedicated hardware component for low-voltage signal transfer and data communication within Honeywell DCS cabinet networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51306356-100 (Rev.A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive wiring component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial communication and control cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Category\u003c\/td\u003e\n\u003ctd\u003eLow-voltage control and data communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding Design\u003c\/td\u003e\n\u003ctd\u003eFoil and\/or braided shield for full EMI\/RFI suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003eMatched characteristic impedance for DCS transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003eHoneywell DCS platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 51306356-100 Rev.A cable assembly maintains structured signal interconnects between system controllers and adjacent I\/O termination blocks. When routed in parallel with analog field lines carrying the 4-20 mA HART loop protocol, the full EMI\/RFI shielding suppresses cross-talk and high-frequency noise coupling.\u003c\/p\u003e\n\u003cp\u003eMaintaining matched characteristic impedance across the conductors minimizes signal reflections during high-speed telemetry transfers, preventing data packet corruption and supporting channel-to-channel isolation parameters across dense cabinet wiring corridors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What shielding implementation is used on the 51306356-100 cable assembly?\u003c\/p\u003e\n\u003cp\u003eA: The cable utilizes full EMI\/RFI suppression shielding consisting of foil and\/or braided shield layers to isolate low-voltage data signals from high-current industrial noise.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 51305356-100 Rev.A assembly be used for direct high-voltage power routing?\u003c\/p\u003e\n\u003cp\u003eA: No, the assembly is specifically engineered for low-voltage control and data communication signals within DCS networks.\u003c\/p\u003e\n\u003cp\u003eQ: How does matched impedance benefit the signal transmission across this cable?\u003c\/p\u003e\n\u003cp\u003eA: Matched characteristic impedance reduces signal attenuation and reflections along the line, ensuring stable data transmission between interconnected system hardware modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that connected system rack backplanes and field power sources are de-energized prior to installing or removing cable connectors.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum allowable bend radii along cabinet wireways to avoid physical stress on internal conductors and shield layers.\u003c\/li\u003e\n\u003cli\u003eBond the cable shield drain wire directly to the cabinet protective earth (PE) grounding bar to maximize noise suppression performance.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables in dedicated low-voltage wiring troughs, keeping physical separation from high-current AC motor leads and power switching lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53197377995061,"sku":"51306356-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51306356-100.jpg?v=1784703717","url":"https:\/\/www.5gplc.com\/products\/honeywell-51306356-100-rev-a-cable-assemblies","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}