{"product_id":"honeywell-51304516-200-smart-mv-transmitter-interface-board","title":"Honeywell 51304516-200 Smart MV Transmitter Interface Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 51304516-200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance Smart Millivolt (MV) Transmitter Interface Board within the Honeywell TDC 3000 and High-Performance Process Manager (HPM) ecosystems. This specialized module captures low-level millivolt signals from field sensors—such as thermocouples and specialized transmitters—and converts them into high-resolution digital data for the control network. We supply this board as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your critical temperature and analytical loops maintain factory-spec calibration and deterministic response times.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 51304516-200 utilizes advanced onboard processing to handle signal linearization and cold-junction compensation directly at the interface level.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51304516-200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSmart MV (Millivolt) Transmitter Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell TDC 3000 \/ HPM \/ APM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-Level Millivolt (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePC Board PLC \/ Add-On Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Factory New\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocalized Logic Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"Smart\" designation indicates that the 51304516-200 handles signal conditioning and engineering unit conversion onboard. This offloads computational tasks from the main controller, reducing system bus traffic and increasing overall loop stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Common-Mode Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board effectively filters out industrial electromagnetic noise that frequently corrupts low-level millivolt signals. By providing high-integrity signal isolation, it prevents \"noisy\" data from triggering false alarms or process oscillations in sensitive thermal loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Calibration Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe -200 revision incorporates upgraded semiconductor components that resist thermal drift. This ensures the board maintains measurement accuracy even in marshalling cabinets subject to ambient temperature fluctuations, a common pain point in non-climate-controlled environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to the exact mechanical specifications of the TDC 3000 chassis, the board slides into standard slots with zero resistance. The high-micron gold plating on the backplane connectors ensures a gas-tight electrical bond, eliminating intermittent communication faults caused by contact oxidation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat differentiates the -200 revision from the earlier -100 series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 51304516-200 typically features updated component logic and improved heat dissipation profiles. It serves as a superior replacement for older revisions, offering enhanced longevity and better resistance to electronic aging in 24\/7 continuous operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board support thermocouple linearization?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The Smart MV Interface Board linearizes standard thermocouple inputs (Type J, K, T, E, etc.) via its onboard processor, providing the DCS with an accurate temperature Process Variable (PV) without requiring secondary external converters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary installation requirements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians must adhere to strict ESD (Electrostatic Discharge) protocols. Use a grounded wrist strap during handling. Ensure the rack configuration matches the board’s I\/O address to facilitate immediate recognition by the system software upon power-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the authenticity of this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery 51304516-200 ships in its original Honeywell factory-sealed antistatic packaging. Each board carries a unique, verifiable serial number and shows no insertion marks on the gold contact fingers, confirming its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52880722559285,"sku":"51304516-200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51304516-200.jpg?v=1778751139","url":"https:\/\/www.5gplc.com\/products\/honeywell-51304516-200-smart-mv-transmitter-interface-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}